Lansing Smith
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 65% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1971
- Net generation, 2025
- 3,747,743 MWh
- Grid
- 230 kV to Florida Power & Light Co (FPL)
- Location
- Bay County, Florida
- Operated by
- Florida Power & Light Co
Operations
- Net generation, 2025
- 3,747,743
MWh - Fuel burned, 2025
- 26,560,875
MMBtu - Capacity factor, 2025
- 64.7
% - Heat rate, 2025
- 7,087
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 2,479,598 | 17,724,495 | — | 7,148 |
| 2025 | 3,747,743 | 26,560,875 | 64.7% | 7,087 |
| 2024 | 3,965,115 | 27,964,349 | 68.2% | 7,053 |
| 2023 | 4,184,498 | 29,221,476 | 72.2% | 6,983 |
| 2022 | 4,542,044 | 31,913,579 | 78.4% | 7,026 |
| 2021 | 4,708,398 | 32,925,797 | 81.2% | 6,993 |
| 2020 | 4,967,565 | 35,161,174 | 85.5% | 7,078 |
| 2019 | 3,913,387 | 27,500,320 | 67.5% | 7,027 |
| 2018 | 4,032,484 | 28,727,491 | 69.6% | 7,124 |
| 2017 | 4,139,059 | 29,509,989 | 71.4% | 7,130 |
| 2016 | 3,507,817 | 25,722,827 | 60.4% | 7,333 |
| 2015 (11 of 12 months) | 3,851,608 | 29,731,865 | — | 7,719 |
| 2014 | 4,506,287 | 36,704,084 | 77.8% | 8,145 |
| 2013 | 4,360,140 | 34,925,782 | 75.2% | 8,010 |
| 2012 | 4,649,697 | 36,356,038 | 80.0% | 7,819 |
| 2011 | 5,028,403 | 40,247,593 | 86.8% | 8,004 |
| 2010 | 4,666,344 | 39,694,770 | 80.5% | 8,507 |
| 2009 | 5,182,946 | 41,738,426 | 89.4% | 8,053 |
| 2008 | 4,739,883 | 41,681,796 | 81.6% | 8,794 |
| 2007 | 4,696,145 | 41,789,914 | 81.0% | 8,899 |
| 2006 | 4,706,050 | 42,387,877 | 81.2% | 9,007 |
| 2005 | 4,422,449 | 39,657,409 | 76.3% | 8,967 |
| 2004 | 4,904,137 | 43,327,316 | 84.4% | 8,835 |
| 2003 (9 of 12 months) | 2,776,879 | 24,387,101 | — | 8,782 |
| 2002 | 4,022,365 | 34,701,754 | 69.4% | 8,627 |
| 2001 | 2,316,371 | 23,737,975 | 40.0% | 10,248 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.