- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Lodi: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Lodi
Power plant · Gas, combustion turbine
Key facts
Power plant · Gas, combustion turbineran 1% of 2025 Standby- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1986
- Net generation, 2025
- 1,927 MWh
- Grid
- 60 kV to City of Lodi - (CA) (CISO)
- Location
- San Joaquin County, California
- Operated by
- Northern California Power AgnySourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 1,927
MWh - Fuel burned, 2025
- 31,368
MMBtu - Capacity factor, 2025
- 0.8
% - Heat rate, 2025
- 16,278
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 1,927 | 31,368 | 0.8% | 16,278 |
| 2024 | 2,823 | 46,765 | 1.2% | 16,566 |
| 2023 | 546 | 9,780 | 0.2% | 17,912 |
| 2022 | 4,682 | 76,314 | 1.9% | 16,299 |
| 2021 | 3,815 | 63,682 | 1.6% | 16,692 |
| 2020 | 2,896 | 47,470 | 1.2% | 16,392 |
| 2019 | 497 | 8,284 | 0.2% | 16,668 |
| 2018 | 3,492 | 56,217 | 1.5% | 16,099 |
| 2017 | 4,132 | 65,832 | 1.7% | 15,932 |
| 2016 | 1,675 | 32,500 | 0.7% | 19,403 |
| 2015 | 2,948 | 45,689 | 1.2% | 15,498 |
| 2014 | 1,263 | 20,023 | 0.5% | 15,854 |
| 2013 | 329 | 5,281 | 0.1% | 16,052 |
| 2012 | 249 | 3,829 | 0.1% | 15,378 |
| 2011 | 417 | 6,577 | 0.2% | 15,772 |
| 2010 | 125 | 2,053 | 0.1% | 16,424 |
| 2009 | 296 | 4,657 | 0.1% | 15,733 |
| 2008 | 178 | 3,026 | 0.1% | 17,000 |
| 2007 | 574 | 9,205 | 0.2% | 16,037 |
| 2006 | 872 | 19,141 | 0.4% | 21,951 |
| 2005 | 2,702 | 41,308 | 1.1% | 15,288 |
| 2004 | 2,859 | 26,801 | 1.2% | 9,374 |
| 2003 | 30,416 | 284,113 | 12.7% | 9,341 |
| 2002 | 38,978 | 354,354 | 16.2% | 9,091 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
2 sourcesSources
- EIA-860M Preliminary Monthly Electric Generator Inventory
- EIA Open Data bulk file — Electricity (ELEC.zip; monthly plant net generation and fuel consumption since 2001)Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)