Show on map
Luke Mill — Power plant · Coal · Verso Luke LLCPea Patch Wind Farm — Wind · MD · 50 MW · 13.0 km away
  • Combustion
  • Retired
  • 10 · 100 · 1,000 MW

Power plant · Coal

Key facts

Power plant · Coalran 34% of 2018 Retired
Capacity
Capacity: sourceEIA-860M · Open licenseMW
Commissioned
1958
Net generation, 2018
194,735 MWh
Location
Allegany County, Maryland
Operated by
Verso Luke LLC

Output

Net generation MWh by year, 2002 to 2019
Fuel burned MMBtu by year, 2002 to 2019
  • Gas
  • Coal
  • Oil
  • Biomass and waste

Operations detail

Details

Who’s behind it

Interested in this project?

Set an alert Book a call Join the beta

Our team gets you what you need.

Beta: private project space · data room · readiness check

Technology
Coal source: “Conventional Steam Coal”
Age
68 years since 1958
All 3 attributes from EIA-860M Preliminary Monthly Electric Generator Inventory
Attributes
AttributeValue
Gem
Parents
Name
Billerud AB
Share pct
100
Gem entity id
E100001001070
Unit ids
G100000106468, G100000106469
Location id
L100000103966
EPA greenhouse gas reporting (GHGRP)
EPA FRS ID
110007334072
NAICS code
322121
Subpart PP (CO2 supply)
No
Subpart RR (geologic sequestration)
No
Subpart UU (CO2 injection)
No
Reporting year
2023
GHGRP facility ID
1001237
Balancing authority codePJM

Retirement

EIA-860M September 2026StatusEvery generator EIA lists at this plant has retired. As of EIA-860M for September 2026.
Retired
May 2019
Capacity retired
65 MW
Generators retired
2
Generators that retired or are scheduled to retire
GeneratorTechnologyNameplateStateDate
GEN1Conventional Steam Coal35 MWRetiredMay 2019
GEN2Conventional Steam Coal30 MWRetiredMay 2019

Grid

EIA-860Grid fieldsAs the plant reported them to EIA-860 (Schedule 2).
Balancing authority
PJM
Transmission lines within 25 km (10)
Can the connection be reused?

A plant that retires usually leaves its substation, transmission connection and interconnection agreement behind, and those may be reusable by a new project at the same site. FERC Order No. 845 lets an interconnection customer use surplus interconnection service at an existing site, and some transmission providers' tariffs let a replacement resource take over a retiring unit's interconnection service, usually within a set time after the retirement. Whether any such right still exists here, who holds it and on what terms depends on the owner, the transmission provider and timing; this page does not establish any of that.

Ownership

2 companies2
Companies with an ownership or operating interest in this asset.
CompanyRoleShareAs ofSource
Verso Luke LLC Operator EIA-860M
VERSO CORP Owner 100.0% 31 Dec 2023 EPA GHGRP

Timeline

  • Stated Units GEN1, GEN2 scheduled to retire, 65 MW · EIA-860M
  • In service · EIA-860M

Sources

6 sources

Sources EIA-860M · GEM · LBNL · EIA · EIA-860M Preliminary Monthly Electric Generator Inventory · EPA Greenhouse Gas Reporting Program — facility register with parent-company shares (Envirofacts pub_dim_facility; FLIGHT)

Sources

Every source and license · Attribution

View at source

Around this plant

Nearby

within 25 km
Projects within 25 km, nearest first.
ProjectKindAwayMW
Pea Patch Wind Farm Postponed Wind 13.0 km 50

Sources EIA-860M

Sources

Attribution