Martinez Refining

Power plant · Gas, combined cycle

Key facts

Power plant · Gas, combined cycleran 84% of 2025 Operating
Capacity
Capacity: sourceEIA-860M · Open licenseMW
Commissioned
1995
Net generation, 2025
733,953 MWh
Grid
115 kV to Pacific Gas & Electric Co (CISO)
Location
Contra Costa County, California

Operations

Net generation, 2025
733,953MWh
Fuel burned, 2025
10,183,604MMBtu
Capacity factor, 2025
83.8%
Heat rate, 2025
13,875Btu/kWh
Capacity factor % of full output, by year
Heat rate Btu per kWh, by year
Net generation, fuel burned, capacity factor and heat rate by year, newest first, as EIA's bulk electricity file states them.
YearNet generation (MWh)Fuel burned (MMBtu)Capacity factorHeat rate (Btu/kWh)
2026 (8 of 12 months)444,0756,474,983—14,581
2025733,95310,183,60483.8%13,875
2024743,60410,329,90384.7%13,892
2023731,47910,119,58783.5%13,834
2022776,76910,282,90888.7%13,238
2021765,25410,556,68087.4%13,795
2020704,8539,968,56680.2%14,143
2019827,53510,625,35294.5%12,840
2018810,83810,964,75292.6%13,523
2017785,59010,526,34089.7%13,399
2016826,18910,477,84194.1%12,682
2015830,6048,152,24994.8%9,815
2014705,9087,243,69180.6%10,262
2013810,5007,870,05792.5%9,710
2012806,9107,770,17291.9%9,630
2011786,0927,814,99889.7%9,942
2010789,8837,689,03190.2%9,734
2009769,7827,752,79087.9%10,071
2008731,2957,590,09183.2%10,379
2007769,3397,892,15587.8%10,258
2006731,0237,853,35583.5%10,743
2005729,3998,732,05783.3%11,972
2004793,8207,459,90890.4%9,398
2003836,4107,275,33195.5%8,698
2002771,8157,059,94888.1%9,147
2001717,5877,294,32581.9%10,165
How these are worked out

Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.

Sources

3 sources

Sources EIA-860M · GEM · EIA

Sources

  • EIA-860MOpen license · retrieved Nov 4, 2026
  • GEMOpen license, with credit · retrieved Oct 26, 2026Global Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
  • EIAOpen license · retrieved Nov 1, 2026Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)

Every source and license · Attribution