- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Martinez Refining: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Martinez Refining
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 84% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1995
- Net generation, 2025
- 733,953 MWh
- Grid
- 115 kV to Pacific Gas & Electric Co (CISO)
- Location
- Contra Costa County, California
- Operated by
- Martinez Refining Co
Operations
- Net generation, 2025
- 733,953
MWh - Fuel burned, 2025
- 10,183,604
MMBtu - Capacity factor, 2025
- 83.8
% - Heat rate, 2025
- 13,875
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 444,075 | 6,474,983 | — | 14,581 |
| 2025 | 733,953 | 10,183,604 | 83.8% | 13,875 |
| 2024 | 743,604 | 10,329,903 | 84.7% | 13,892 |
| 2023 | 731,479 | 10,119,587 | 83.5% | 13,834 |
| 2022 | 776,769 | 10,282,908 | 88.7% | 13,238 |
| 2021 | 765,254 | 10,556,680 | 87.4% | 13,795 |
| 2020 | 704,853 | 9,968,566 | 80.2% | 14,143 |
| 2019 | 827,535 | 10,625,352 | 94.5% | 12,840 |
| 2018 | 810,838 | 10,964,752 | 92.6% | 13,523 |
| 2017 | 785,590 | 10,526,340 | 89.7% | 13,399 |
| 2016 | 826,189 | 10,477,841 | 94.1% | 12,682 |
| 2015 | 830,604 | 8,152,249 | 94.8% | 9,815 |
| 2014 | 705,908 | 7,243,691 | 80.6% | 10,262 |
| 2013 | 810,500 | 7,870,057 | 92.5% | 9,710 |
| 2012 | 806,910 | 7,770,172 | 91.9% | 9,630 |
| 2011 | 786,092 | 7,814,998 | 89.7% | 9,942 |
| 2010 | 789,883 | 7,689,031 | 90.2% | 9,734 |
| 2009 | 769,782 | 7,752,790 | 87.9% | 10,071 |
| 2008 | 731,295 | 7,590,091 | 83.2% | 10,379 |
| 2007 | 769,339 | 7,892,155 | 87.8% | 10,258 |
| 2006 | 731,023 | 7,853,355 | 83.5% | 10,743 |
| 2005 | 729,399 | 8,732,057 | 83.3% | 11,972 |
| 2004 | 793,820 | 7,459,908 | 90.4% | 9,398 |
| 2003 | 836,410 | 7,275,331 | 95.5% | 8,698 |
| 2002 | 771,815 | 7,059,948 | 88.1% | 9,147 |
| 2001 | 717,587 | 7,294,325 | 81.9% | 10,165 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)