Mitchell (WV) — Power plant · Coal · Kentucky Power Co
  • Combustion
  • Operating
  • 10 · 100 · 1,000 MW

Mitchell (WV)

Power plant · Coal

Key facts

Power plant · Coalran 28% of 2025 Operating
Capacity
Capacity: sourceEIA-860M · Open licenseMW
Commissioned
1971
Net generation, 2025
3,950,432 MWh
Grid
765 kV to Ohio Power Co (PJM)
Location
Marshall County, West Virginia

Operations

Net generation, 2025
3,950,432MWh
Fuel burned, 2025
42,041,944MMBtu
Capacity factor, 2025
27.6%
Heat rate, 2025
10,642Btu/kWh
Capacity factor % of full output, by year
Heat rate Btu per kWh, by year
Net generation, fuel burned, capacity factor and heat rate by year, newest first, as EIA's bulk electricity file states them.
YearNet generation (MWh)Fuel burned (MMBtu)Capacity factorHeat rate (Btu/kWh)
2026 (8 of 12 months)2,409,64825,202,920—10,459
20253,950,43242,041,94427.6%10,642
20244,090,17744,739,21028.5%10,938
20233,327,30435,982,02223.3%10,814
20223,501,88738,092,76124.5%10,878
20214,769,10450,105,68933.4%10,506
20203,611,72038,196,90325.2%10,576
20195,040,70753,999,20835.2%10,713
20185,503,29159,435,44938.5%10,800
20177,686,84776,623,37353.8%9,968
20167,683,74677,944,09953.6%10,144
20155,367,81954,127,36637.5%10,084
20148,506,34083,111,05759.5%9,770
20135,956,99159,778,20941.6%10,035
20127,544,33875,663,36052.6%10,029
20119,124,43589,674,71063.8%9,828
201010,242,06199,917,52271.6%9,756
20099,389,85092,127,29765.7%9,811
200810,638,648104,765,45274.2%9,848
20078,777,63082,043,64761.4%9,347
20067,609,04973,376,73053.2%9,643
20056,931,90868,296,45848.5%9,852
20049,100,75089,101,62063.5%9,791
20039,636,57793,582,23367.4%9,711
20029,231,56789,359,44664.5%9,680
20018,139,86978,336,00456.9%9,624
How these are worked out

Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.

Sources

3 sources

Sources EIA-860M · GEM · EIA

Sources

  • EIA-860MOpen license · retrieved Nov 4, 2026
  • GEMOpen license, with credit · retrieved Oct 26, 2026Global Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
  • EIAOpen license · retrieved Nov 1, 2026Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)

Every source and license · Attribution

View at source