Show on map
Mountainview Generating Station — Power plant · Gas, combined cycle · Southern California Edison Co
  • Combustion
  • Operating
  • 10 · 100 · 1,000 MW

Mountainview Generating Station

Power plant · Gas, combined cycle

Key facts

Power plant · Gas, combined cycleran 15% of 2025 Operating
Capacity
Capacity: sourceEIA-860M · Open licenseMW
Commissioned
2005
Net generation, 2025
1,371,673 MWh
Grid
220 kV to Southern California Edison Co (CISO)
Location
San Bernardino County, California

Operations

Net generation, 2025
1,371,673MWh
Fuel burned, 2025
10,752,702MMBtu
Capacity factor, 2025
15.1%
Heat rate, 2025
7,839Btu/kWh
Capacity factor % of full output, by year
Heat rate Btu per kWh, by year
Net generation, fuel burned, capacity factor and heat rate by year, newest first, as EIA's bulk electricity file states them.
YearNet generation (MWh)Fuel burned (MMBtu)Capacity factorHeat rate (Btu/kWh)
2026 (8 of 12 months)679,6575,693,042—8,376
20251,371,67310,752,70215.1%7,839
20242,493,39819,632,01027.4%7,874
20232,552,46520,603,13228.1%8,072
20223,755,56529,179,27541.3%7,770
20212,025,78416,117,14822.3%7,956
20202,866,90022,664,16831.5%7,906
20193,040,68823,535,77533.5%7,740
20182,091,87516,733,88323.0%8,000
20174,040,50731,708,21144.5%7,848
20164,890,77237,701,95053.7%7,709
20155,750,40944,001,66563.3%7,652
20146,172,66346,054,80768.0%7,461
20135,518,34240,620,96760.8%7,361
20126,586,44748,849,53372.3%7,417
20114,631,48034,947,97651.0%7,546
20106,034,35545,531,12666.4%7,545
20095,749,67143,862,60963.3%7,629
20086,691,29549,996,82573.5%7,472
20076,308,44746,499,10369.5%7,371
20064,866,12035,309,84953.6%7,256
2005148,5591,075,3511.6%7,238
200200——
200138,269421,6810.4%11,019
How these are worked out

Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.

Sources

3 sources

Sources EIA-860M · GEM · EIA

Sources

  • EIA-860MOpen license · retrieved Nov 4, 2026
  • GEMOpen license, with credit · retrieved Oct 26, 2026Global Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
  • EIAOpen license · retrieved Nov 1, 2026Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)

Every source and license · Attribution

View at source