- Bioenergy
- Operating
- 10 · 100 · 1,000 MW
Map
- Bioenergy
- Operating
NE Renewable Tamworth, LLC: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
NE Renewable Tamworth, LLC
Power plant · Biomass
Key facts
Power plant · Biomassran 36% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1987
- Net generation, 2025
- 77,777 MWh
- Grid
- 115 kV to Public Service Co of NH (ISNE)
- Location
- Carroll County, New Hampshire
- Operated by
- NE Renewable Tamworth, LLCSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 77,777
MWh - Fuel burned, 2025
- 1,299,382
MMBtu - Capacity factor, 2025
- 35.5
% - Heat rate, 2025
- 16,706
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 77,777 | 1,299,382 | 35.5% | 16,706 |
| 2024 | 0 | 0 | — | — |
| 2023 | 0 | 0 | — | — |
| 2022 | 21,937 | 302,311 | 10.0% | 13,781 |
| 2021 | 57,567 | 862,218 | 26.3% | 14,978 |
| 2020 | 46,968 | 725,599 | 21.4% | 15,449 |
| 2019 | 113,672 | 1,956,879 | 51.9% | 17,215 |
| 2018 | 92,855 | 1,546,002 | 42.4% | 16,650 |
| 2017 | 155,354 | 2,536,578 | 70.9% | 16,328 |
| 2016 | 119,374 | 1,863,342 | 54.4% | 15,609 |
| 2015 | 154,444 | 2,908,584 | 70.5% | 18,833 |
| 2014 | 166,033 | 2,941,551 | 75.8% | 17,717 |
| 2013 | 159,980 | 2,882,547 | 73.0% | 18,018 |
| 2012 | 159,849 | 2,844,153 | 72.8% | 17,793 |
| 2011 | 149,122 | 2,501,271 | 68.1% | 16,773 |
| 2010 | 157,753 | 2,684,214 | 72.0% | 17,015 |
| 2009 | 158,886 | 2,766,294 | 72.5% | 17,411 |
| 2008 | 155,993 | 2,554,614 | 71.0% | 16,376 |
| 2007 | 174,552 | 2,880,945 | 79.7% | 16,505 |
| 2006 | 174,148 | 2,953,788 | 79.5% | 16,961 |
| 2005 | 169,852 | 2,752,659 | 77.6% | 16,206 |
| 2004 | 176,490 | 2,916,519 | 80.4% | 16,525 |
| 2003 | 171,399 | 2,566,196 | 78.3% | 14,972 |
| 2002 | 169,660 | 2,638,790 | 77.5% | 15,553 |
| 2001 | 169,140 | 2,602,956 | 77.2% | 15,389 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)