Show on map
Nevada Cogen Assoc#1 GarnetVly — Power plant · Gas, combined cycle · Nevada Cogeneration Assoc # 1
  • Combustion
  • Operating
  • 10 · 100 · 1,000 MW

Nevada Cogen Assoc#1 GarnetVly

Power plant · Gas, combined cycle

Key facts

Power plant · Gas, combined cycleran 37% of 2025 Retiring
Capacity
Capacity: sourceEIA-860M · Open licenseMW
Commissioned
1992
Net generation, 2025
305,193 MWh
Grid
138 kV to Nevada Power Co (NEVP)
Location
Clark County, Nevada

Operations

Net generation, 2025
305,193MWh
Fuel burned, 2025
2,703,009MMBtu
Capacity factor, 2025
36.8%
Heat rate, 2025
8,857Btu/kWh
Capacity factor % of full output, by year
Heat rate Btu per kWh, by year
Net generation, fuel burned, capacity factor and heat rate by year, newest first, as EIA's bulk electricity file states them.
YearNet generation (MWh)Fuel burned (MMBtu)Capacity factorHeat rate (Btu/kWh)
2026 (8 of 12 months)186,4351,664,099—8,926
2025305,1932,703,00936.8%8,857
2024429,5223,784,80451.6%8,812
2023459,3494,183,17655.3%9,107
2022713,9836,748,88586.0%9,452
2021716,0866,711,47486.2%9,372
2020724,3756,716,66287.0%9,272
2019709,6306,550,20385.5%9,230
2018722,8026,677,99687.0%9,239
2017690,6096,310,78483.2%9,138
2016725,5536,569,80287.1%9,055
2015722,9216,593,32187.1%9,120
2014726,7895,911,72087.5%8,134
2013721,1066,740,49886.8%9,347
2012703,6726,416,73184.5%9,119
2011723,0766,491,75887.1%8,978
2010729,6856,512,65587.9%8,925
2009720,8696,481,74686.8%8,992
2008670,1076,057,47380.5%9,040
2007701,6416,347,25884.5%9,046
2006693,6226,402,93983.5%9,231
2005693,9996,393,85483.6%9,213
2004703,9256,559,59484.5%9,319
2003718,5526,536,54586.5%9,097
2002720,7696,320,44386.8%8,769
2001728,5276,449,82587.7%8,853
How these are worked out

Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.

Sources

3 sources

Sources EIA-860M · GEM · EIA

Sources

  • EIA-860MOpen license · retrieved Nov 4, 2026
  • GEMOpen license, with credit · retrieved Oct 26, 2026Global Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
  • EIAOpen license · retrieved Nov 1, 2026Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)

Every source and license · Attribution