Show on map
New Mexico State University — Power plant · Gas, combustion turbine · NEW MEXICO STATE UNIVERSITY
  • Combustion
  • Operating
  • 10 · 100 · 1,000 MW

New Mexico State University

Power plant · Gas, combustion turbine

Key facts

Power plant · Gas, combustion turbineran 76% of 2025 Operating
Capacity
Capacity: sourceEIA-860M · Open licenseMW
Commissioned
1996
Net generation, 2025
31,383 MWh
Grid
14 kV to El Paso Electric Co (EPE)
Location
Dona Ana County, New Mexico
Operated by
New Mexico State UniversitySourceEIA-860M Preliminary Monthly Electric Generator Inventory

Operations

Net generation, 2025
31,383MWh
Fuel burned, 2025
410,909MMBtu
Capacity factor, 2025
76.2%
Heat rate, 2025
13,093Btu/kWh
Capacity factor % of full output, by year
Heat rate Btu per kWh, by year
Net generation, fuel burned, capacity factor and heat rate by year, newest first, as EIA's bulk electricity file states them.
YearNet generation (MWh)Fuel burned (MMBtu)Capacity factorHeat rate (Btu/kWh)
2026 (7 of 12 months)17,801242,282—13,611
202531,383410,90976.2%13,093
202431,356418,46475.9%13,346
202329,640409,35272.0%13,811
202234,365456,02783.5%13,270
202135,115464,08685.3%13,216
202033,649455,51781.5%13,537
201936,228483,34088.0%13,342
201831,843431,68777.3%13,557
201736,524476,06288.7%13,034
201637,689509,06791.3%13,507
201537,113471,54290.1%12,706
201434,948444,91584.9%12,731
201338,142462,99192.6%12,139
201232,791458,93379.4%13,996
201138,395483,38893.3%12,590
201038,929493,90094.5%12,687
200936,567472,03488.8%12,909
200832,465474,18378.6%14,606
200736,066483,30687.6%13,401
200629,625413,94272.0%13,972
200529,384219,89971.4%7,484
200436,505487,03288.4%13,342
200342,203527,908102.5%12,509
200241,790515,032101.5%12,324
200139,748494,74496.5%12,447
How these are worked out

Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.

Sources

2 sources

Sources EIA-860M · EIA

Sources

  • EIA-860MOpen license · retrieved Nov 4, 2026
  • EIAOpen license · retrieved Nov 1, 2026Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)

Every source and license · Attribution

View at source