- Wind & solar
- Operating
- 10 · 100 · 1,000 MW
Map
- Wind & solar
- Operating
Northern Colorado Wind LLC: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Northern Colorado Wind LLC
Power plant · Wind
Key facts
Power plant · Windran 35% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2009
- Net generation, 2025
- 530,784 MWh
- Grid
- 230 kV to Public Service Co of Colorado (PSCO)
- Location
- Logan County, Colorado
- Operated by
- Northern Colorado Wind LLCSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 530,784
MWh - Fuel burned, 2025
- 1,811,035
MMBtu - Capacity factor, 2025
- 34.8
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 530,784 | 1,811,035 | 34.8% | — |
| 2024 | 557,526 | 1,902,279 | 36.4% | — |
| 2023 | 517,292 | 1,765,001 | 33.9% | — |
| 2022 | 573,988 | 1,958,448 | 37.6% | — |
| 2021 | 452,025 | 3,997,709 | 29.6% | — |
| 2020 | 466,260 | 4,087,702 | 30.4% | — |
| 2019 | 351,488 | 3,130,000 | 23.0% | — |
| 2018 | 403,903 | 3,677,134 | 26.5% | — |
| 2017 | 464,957 | 4,283,649 | 30.4% | — |
| 2016 | 382,398 | 3,530,299 | 25.0% | — |
| 2015 | 428,432 | 3,992,557 | 28.1% | — |
| 2014 | 468,790 | 4,458,191 | 30.7% | — |
| 2013 | 539,543 | 5,147,779 | 35.3% | — |
| 2012 | 528,989 | 5,033,859 | 34.5% | — |
| 2011 | 566,204 | 5,501,239 | 37.1% | — |
| 2010 | 446,350 | 4,354,589 | 29.2% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)