Northside Generating Station
Power plant · Coal
Operations
- Net generation, 2025
- 2,854,596
MWh - Fuel burned, 2025
- 31,735,259
MMBtu - Capacity factor, 2025
- 23.2
% - Heat rate, 2025
- 11,117
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 2,483,615 | 27,630,942 | — | 11,125 |
| 2025 | 2,854,596 | 31,735,259 | 23.2% | 11,117 |
| 2024 | 2,906,105 | 33,447,840 | 23.5% | 11,510 |
| 2023 | 3,191,859 | 35,753,888 | 25.9% | 11,202 |
| 2022 | 3,313,756 | 36,857,120 | 26.9% | 11,122 |
| 2021 | 3,209,817 | 34,573,353 | 26.0% | 10,771 |
| 2020 | 4,645,080 | 48,596,713 | 37.6% | 10,462 |
| 2019 | 3,878,239 | 39,653,871 | 31.5% | 10,225 |
| 2018 | 4,278,073 | 45,241,295 | 34.7% | 10,575 |
| 2017 | 2,870,527 | 30,065,875 | 23.3% | 10,474 |
| 2016 | 4,733,029 | 47,692,696 | 38.3% | 10,077 |
| 2015 | 3,787,824 | 39,281,900 | 30.7% | 10,371 |
| 2014 | 3,709,208 | 38,522,239 | 30.1% | 10,386 |
| 2013 | 2,770,815 | 28,919,910 | 22.5% | 10,437 |
| 2012 | 2,364,018 | 26,637,996 | 19.1% | 11,268 |
| 2011 | 3,193,251 | 33,887,086 | 25.9% | 10,612 |
| 2010 | 4,319,359 | 43,365,835 | 35.0% | 10,040 |
| 2009 | 4,045,683 | 40,474,233 | 32.8% | 10,004 |
| 2008 | 4,359,661 | 44,490,098 | 35.3% | 10,205 |
| 2007 | 4,570,793 | 42,932,852 | 37.1% | 9,393 |
| 2006 | 4,491,183 | 45,918,996 | 36.4% | 10,224 |
| 2005 | 4,976,838 | 50,213,325 | 40.4% | 10,089 |
| 2004 | 4,670,022 | 48,206,714 | 37.8% | 10,323 |
| 2003 | 4,724,993 | 48,641,433 | 38.3% | 10,294 |
| 2002 | 3,713,143 | 39,453,184 | 30.1% | 10,625 |
| 2001 | 2,686,013 | 28,184,362 | 21.8% | 10,493 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.