Ocoee 1
Power plant · Hydro
Key facts
Power plant · Hydroran 39% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1912
- Net generation, 2025
- 65,629 MWh
- Grid
- 69 kV to Tennessee Valley Authority (TVA)
- Location
- Polk County, Tennessee
- Operated by
- Tennessee Valley AuthoritySourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 65,629
MWh - Fuel burned, 2025
- 223,926
MMBtu - Capacity factor, 2025
- 39.4
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 65,629 | 223,926 | 39.4% | — |
| 2024 | 69,233 | 236,222 | 41.5% | — |
| 2023 | 69,797 | 238,146 | 41.9% | — |
| 2022 | 86,208 | 294,141 | 51.8% | — |
| 2021 | 111,157 | 983,071 | 66.8% | — |
| 2020 | 136,852 | 1,199,782 | 82.0% | — |
| 2019 | 108,616 | 967,226 | 65.3% | — |
| 2018 | 103,594 | 943,120 | 62.2% | — |
| 2017 | 54,738 | 504,301 | 32.9% | — |
| 2016 | 67,852 | 626,409 | 40.7% | — |
| 2015 | 86,114 | 802,497 | 51.7% | — |
| 2014 | 74,755 | 710,920 | 44.9% | — |
| 2013 | 112,641 | 1,074,709 | 67.7% | — |
| 2012 | 50,481 | 480,378 | 30.2% | — |
| 2011 | 53,958 | 524,254 | 32.4% | — |
| 2010 | 78,936 | 770,100 | 47.4% | — |
| 2009 | 32,183 | 314,108 | 19.3% | — |
| 2008 | 40,113 | 395,273 | 24.0% | — |
| 2007 | 36,566 | 361,417 | 22.0% | — |
| 2006 | 55,993 | 555,395 | 33.6% | — |
| 2005 | 88,727 | 887,181 | 53.3% | — |
| 2004 | 54,536 | 546,560 | 32.7% | — |
| 2003 | 96,170 | 984,877 | 57.8% | — |
| 2002 | 71,114 | 723,443 | 42.7% | — |
| 2001 | 53,111 | 548,796 | 31.9% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.