- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Pratt 2: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Pratt 2
Power plant · Gas, reciprocating engine
Key facts
Power plant · Gas, reciprocating engineran 0% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1994
- Net generation, 2025
- 195 MWh
- Grid
- 115 kV to City of Pratt- (KS) (SWPP)
- Location
- Pratt County, Kansas
- Operated by
- City of Pratt- (KS)SourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 195
MWh - Fuel burned, 2025
- 2,081
MMBtu - Capacity factor, 2025
- 0.1
% - Heat rate, 2025
- 10,672
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 195 | 2,081 | 0.1% | 10,672 |
| 2024 | 372 | 3,650 | 0.3% | 9,812 |
| 2023 | 226 | 2,721 | 0.2% | 12,040 |
| 2022 | 331 | 3,387 | 0.2% | 10,233 |
| 2021 | 206 | 2,840 | 0.1% | 13,786 |
| 2020 | 207 | 2,141 | 0.1% | 10,343 |
| 2019 | 249 | 2,579 | 0.2% | 10,357 |
| 2018 | 502 | 4,385 | 0.4% | 8,735 |
| 2017 | 253 | 3,327 | 0.2% | 13,150 |
| 2016 | 887 | 7,167 | 0.6% | 8,080 |
| 2015 | 1,243 | 16,026 | 0.9% | 12,893 |
| 2014 | 691 | 28,513 | 0.5% | — |
| 2013 | 1,598 | 19,598 | 1.1% | 12,264 |
| 2012 | 6,467 | 66,972 | 4.6% | 10,356 |
| 2011 | 1,855 | 20,420 | 1.3% | 11,008 |
| 2010 | 2,711 | 31,927 | 1.9% | 11,777 |
| 2009 | 1,758 | 25,727 | 1.2% | 14,634 |
| 2008 | 1,088 | 16,269 | 0.8% | 14,953 |
| 2007 | -283 | 35,566 | — | — |
| 2006 | 386 | 7,099 | 0.3% | 18,391 |
| 2005 | 2,334 | 46,973 | 1.7% | 20,126 |
| 2004 | 407 | 9,804 | 0.3% | 24,088 |
| 2003 | 855 | 17,874 | 0.6% | 20,905 |
| 2002 | 375 | 6,243 | 0.3% | 16,648 |
| 2001 | 929 | 13,353 | 0.7% | 14,374 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.