RCWMD Badlands Landfill Gas Project: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
RCWMD Badlands Landfill Gas Project
Power plant · Biomass
Key facts
Power plant · Biomassran 54% of 2016 Retired- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2001
- Net generation, 2016
- 6,208 MWh
- Location
- Riverside County, California
- Operated by
- Riverside County Waste Management DeptSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2016
- 6,208
MWh - Fuel burned, 2016
- 95,249
MMBtu - Capacity factor, 2016
- 54.4
% - Heat rate, 2016
- 15,343
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2017 (9 of 12 months) | 2,998 | 45,700 | — | 15,244 |
| 2016 | 6,208 | 95,249 | 54.4% | 15,343 |
| 2015 | 5,723 | 86,775 | 50.2% | 15,162 |
| 2014 | 1,873 | 26,625 | 16.4% | 14,215 |
| 2013 | 3,860 | 43,868 | 33.9% | 11,365 |
| 2012 | 2,604 | 29,819 | 22.8% | 11,451 |
| 2011 | 3,696 | 48,672 | 32.5% | 13,169 |
| 2010 | 6,275 | 82,133 | 55.1% | 13,089 |
| 2009 | 6,311 | 82,704 | 55.4% | 13,105 |
| 2008 | 5,351 | 57,922 | 46.9% | 10,824 |
| 2007 | 3,246 | 44 | 28.5% | — |
| 2006 | 5,764 | 81,588 | 50.6% | 14,155 |
| 2005 | 5,630 | 55,792 | 49.4% | 9,910 |
| 2004 | 3,250 | 38,328 | 28.5% | 11,793 |
| 2003 | 2,820 | 29,177 | 24.8% | 10,346 |
| 2002 | 2,035 | 23,100 | 17.9% | 11,351 |
| 2001 (1 of 12 months) | 2,389 | 32,170 | — | 13,466 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.