Show on map
Roseton Generating Facility — Power plant · Gas, steam turbine · Roseton Generating LLC
  • Combustion
  • Operating
  • 10 · 100 · 1,000 MW

Roseton Generating Facility

Power plant · Gas, steam turbine

Key facts

Power plant · Gas, steam turbineran 6% of 2025 Operating
Capacity
Capacity: sourceEIA-860M · Open licenseMW
Commissioned
1974
Net generation, 2025
676,128 MWh
Grid
345 kV to Central Hudson Gas & Elec Corp (NYIS)
Location
Orange County, New York

Operations

Net generation, 2025
676,128MWh
Fuel burned, 2025
7,695,689MMBtu
Capacity factor, 2025
6.2%
Heat rate, 2025
11,382Btu/kWh
Capacity factor % of full output, by year
Heat rate Btu per kWh, by year
Net generation, fuel burned, capacity factor and heat rate by year, newest first, as EIA's bulk electricity file states them.
YearNet generation (MWh)Fuel burned (MMBtu)Capacity factorHeat rate (Btu/kWh)
2026 (8 of 12 months)397,0334,578,720—11,532
2025676,1287,695,6896.2%11,382
2024236,6582,763,5322.2%11,677
2023192,7142,282,4741.8%11,844
2022477,7285,157,0504.4%10,795
2021138,8601,648,2331.3%11,870
2020108,6821,297,9011.0%11,942
2019143,6751,774,3971.3%12,350
2018516,5085,692,4534.8%11,021
2017316,4413,592,4002.9%11,352
2016301,1833,444,2822.8%11,436
2015478,0325,269,0664.4%11,022
2014375,1524,155,1183.5%11,076
2013298,4883,508,7092.7%11,755
2012425,6704,910,5183.9%11,536
2011300,4333,537,8642.8%11,776
2010467,6265,381,9084.3%11,509
2009431,4624,582,8624.0%10,622
2008446,5844,835,0514.1%10,827
20071,076,20611,116,3009.9%10,329
2006433,4744,800,8474.0%11,075
20053,494,15136,155,50532.1%10,347
20043,771,00038,833,03634.6%10,298
20033,238,07133,300,23629.8%10,284
20021,211,54913,135,99711.1%10,842
20012,516,11126,478,60723.1%10,524
How these are worked out

Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.

Sources

2 sources

Sources EIA-860M · EIA

Sources

  • EIA-860MOpen license · retrieved Nov 4, 2026
  • EIAOpen license · retrieved Nov 1, 2026Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)

Every source and license · Attribution

View at source