Show on map
Rupert Cogen Project — Power plant · Gas, combined cycle · Energy Operations Group, LLCConner Ridge — Postponed · Wind · ID · 19.5 MW · 7.6 mi awayChapin Mountain — Postponed · Wind · ID · 19.5 MW · 8.7 mi awayBonanza Bar — Postponed · Wind · ID · 20 MW · 11.1 mi away
  • Combustion
  • Retired
  • 10 · 100 · 1,000 MW

Rupert Cogen Project

Power plant · Gas, combined cycle

Key facts

Power plant · Gas, combined cycleran 72% of 2016 Retired
Capacity
Capacity: sourceEIA-860M · Open licenseMW
Commissioned
1996
Net generation, 2016
65,841 MWh
Location
Minidoka County, Idaho

Output

Net generation MWh by year, 2001 to 2016
Fuel burned MMBtu by year, 2001 to 2016
  • Gas

Operations detail

Details

Who’s behind it

Interested in this project?

Set an alert Book a call Join the beta

Our team gets you what you need.

Beta: private project space · data room · readiness check

Technology
Gas, combined cycle source: “Natural Gas Fired Combined Cycle”
Age
30 years since 1996
All 2 attributes from EIA-860M Preliminary Monthly Electric Generator Inventory
Attributes
AttributeValue
EPA greenhouse gas reporting (GHGRP)
EPA FRS ID
110028021600
NAICS code
221112
Subpart PP (CO2 supply)
No
Subpart RR (geologic sequestration)
No
Subpart UU (CO2 injection)
No
Reporting year
2023
GHGRP facility ID
1000577
Balancing authority codeBPAT

Retirement

EIA-860M September 2026StatusEvery generator EIA lists at this plant has retired. As of EIA-860M for September 2026.
Retired
November 2016
Capacity retired
10.4 MW
Generators retired
1
Generators that retired or are scheduled to retire
GeneratorTechnologyNameplateStateDate
1002Natural Gas Fired Combined Cycle10.4 MWRetiredNovember 2016

Grid

EIA-860Grid fieldsAs the plant reported them to EIA-860 (Schedule 2).
Balancing authority
BPAT
Can the connection be reused?

A plant that retires usually leaves its substation, transmission connection and interconnection agreement behind, and those may be reusable by a new project at the same site. FERC Order No. 845 lets an interconnection customer use surplus interconnection service at an existing site, and some transmission providers' tariffs let a replacement resource take over a retiring unit's interconnection service, usually within a set time after the retirement. Whether any such right still exists here, who holds it and on what terms depends on the owner, the transmission provider and timing; this page does not establish any of that.

Ownership

2 companies2
Companies with an ownership or operating interest in this asset.
CompanyRoleShareAs ofSource
Energy Operations Group, LLC Operator EIA-860M
Rupert Holdings, LLC Owner 100.0% Dec 31, 2023 EPA GHGRP

Timeline

  • Stated Unit 1002 scheduled to retire, 10.4 MW · EIA-860M
  • In service · EIA-860M

Around this plant

Nearby

within 15 mi
Projects within 15 mi, nearest first.
ProjectKindAwayMW
Conner Ridge Postponed Wind 7.6 mi 19.5
Chapin Mountain Postponed Wind 8.7 mi 19.5
Bonanza Bar Postponed Wind 11.1 mi 20

Sources EIA-860M

Sources

  • EIA-860MOpen license · retrieved Nov 4, 2026

Attribution