Sacramento Municipal Util Dist
Power plant · Hydro
Key facts
Power plant · Hydroran 23% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1985
- Net generation, 2025
- 14,237 MWh
- Grid
- 60 kV to Pacific Gas & Electric Co (CISO)
- Location
- Placer County, California
- Operated by
- South Sutter Water DistrictSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 14,237
MWh - Fuel burned, 2025
- 48,578
MMBtu - Capacity factor, 2025
- 22.6
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 14,237 | 48,578 | 22.6% | — |
| 2024 | 7,306 | 24,928 | 11.6% | — |
| 2023 | 22,655 | 77,299 | 35.9% | — |
| 2022 | 6,439 | 21,971 | 10.2% | — |
| 2021 | 1,925 | 17,024 | 3.0% | — |
| 2020 | 12,911 | 113,190 | 20.4% | — |
| 2019 | 29,529 | 262,955 | 46.8% | — |
| 2018 | 25,365 | 230,924 | 40.2% | — |
| 2017 | 40,505 | 373,174 | 64.2% | — |
| 2016 | 27,711 | 255,827 | 43.8% | — |
| 2015 | 5,251 | 48,935 | 8.3% | — |
| 2014 | 5,767 | 54,844 | 9.1% | — |
| 2013 | 12,807 | 122,192 | 20.3% | — |
| 2012 | 22,404 | 213,195 | 35.4% | — |
| 2011 | 38,368 | 372,783 | 60.8% | — |
| 2010 | 27,786 | 271,079 | 44.0% | — |
| 2009 | 22,145 | 216,135 | 35.1% | — |
| 2008 | 11,720 | 115,490 | 18.5% | — |
| 2007 | 11,810 | 116,731 | 18.7% | — |
| 2006 | 34,255 | 339,775 | 54.3% | — |
| 2005 | 26,596 | 265,933 | 42.2% | — |
| 2004 | 21,569 | 216,165 | 34.1% | — |
| 2003 | 30,855 | 315,986 | 48.9% | — |
| 2002 | 26,786 | 272,494 | 42.5% | — |
| 2001 | 3,591 | 37,106 | 5.7% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.