Sagamore Plant Cogeneration
Power plant · Gas, steam turbine
Key facts
Power plant · Gas, steam turbineran 33% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1984
- Net generation, 2025
- 21,293 MWh
- Grid
- 12 kV to Duke Energy Indiana Inc (MISO)
- Location
- Tippecanoe County, Indiana
- Operated by
- Tate & Lyle Ingredients Americas Inc
Operations
- Net generation, 2025
- 21,293
MWh - Fuel burned, 2025
- 1,059,538
MMBtu - Capacity factor, 2025
- 32.9
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 17,326 | 870,174 | — | — |
| 2025 | 21,293 | 1,059,538 | 32.9% | — |
| 2024 | 19,511 | 1,200,020 | 30.0% | — |
| 2023 | 16,833 | 1,414,038 | 26.0% | — |
| 2022 | 31,878 | 1,601,650 | 49.2% | — |
| 2021 | 6,890 | 1,337,056 | 10.6% | — |
| 2020 | 9,889 | 383,424 | 15.2% | — |
| 2019 | 27,337 | 1,320,030 | 42.2% | — |
| 2018 | 37,502 | 1,876,979 | 57.9% | — |
| 2017 | 27,621 | 1,632,812 | 42.6% | — |
| 2016 | 1,247 | 1,623,079 | 1.9% | — |
| 2015 | 20,985 | 1,637,249 | 32.4% | — |
| 2014 | 25,817 | 1,203,006 | 39.8% | — |
| 2013 | 18,023 | 1,189,929 | 27.8% | — |
| 2012 | 37,685 | 1,379,356 | 58.0% | — |
| 2011 | 34,864 | 1,594,122 | 53.8% | — |
| 2010 | 33,541 | 1,579,755 | 51.7% | — |
| 2009 | 32,781 | 1,517,482 | 50.6% | — |
| 2008 | 34,641 | 1,523,879 | 53.3% | — |
| 2007 | 41,086 | 1,513,474 | 63.4% | — |
| 2006 | 39,875 | 1,470,428 | 61.5% | — |
| 2005 | 41,769 | 1,526,379 | 64.4% | — |
| 2004 | 34,649 | 1,528,754 | 53.3% | — |
| 2002 | 38,008 | 2,566,301 | 58.6% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.