- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Southern Minnesota Beet Sugar: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Southern Minnesota Beet Sugar
Power plant · Coal
Key facts
Power plant · Coalran 39% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1976
- Net generation, 2025
- 25,528 MWh
- Grid
- 69 kV, 13 kV, 5 kV to Renville-Sibley Coop Pwr Assn (MISO)
- Location
- Renville County, Minnesota
- Operated by
- Southern Minnesota Beet SugarSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 25,528
MWh - Fuel burned, 2025
- 3,812,597
MMBtu - Capacity factor, 2025
- 38.9
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 13,028 | 2,419,807 | — | — |
| 2025 | 25,528 | 3,812,597 | 38.9% | — |
| 2024 | 27,169 | 4,427,226 | 41.2% | — |
| 2023 | 30,067 | 4,361,405 | 45.8% | — |
| 2022 | 23,998 | 4,404,442 | 36.5% | — |
| 2021 | 16,862 | 4,005,178 | 25.7% | — |
| 2020 | 14,709 | 4,145,041 | 22.3% | — |
| 2019 | 19,684 | 3,358,359 | 30.0% | — |
| 2018 | 17,908 | 4,573,503 | 27.3% | — |
| 2017 | 20,816 | 4,148,108 | 31.7% | — |
| 2016 | 17,369 | 3,839,166 | 26.4% | — |
| 2015 | 10,878 | 4,572,365 | 16.6% | — |
| 2014 | 10,469 | 3,014,999 | 15.9% | — |
| 2013 | 6,190 | 3,089,202 | 9.4% | — |
| 2012 | 12,779 | 3,141,694 | 19.4% | — |
| 2011 | 13,671 | 3,426,041 | 20.8% | — |
| 2010 | 9,083 | 3,455,463 | 13.8% | — |
| 2009 | 1 | 3,379,112 | 0.0% | — |
| 2008 | 1 | 3,176,241 | 0.0% | — |
| 2007 | 1 | 3,284,404 | 0.0% | — |
| 2006 | 1 | 3,355,479 | 0.0% | — |
| 2005 | 1 | 2,709,640 | 0.0% | — |
| 2004 | 1 | 3,199,911 | 0.0% | — |
| 2003 | 1 | 2,997,415 | 0.0% | — |
| 2002 | 563 | 3,087,374 | 0.9% | — |
| 2001 | 14,847 | 9,649,784 | 22.6% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.