Spaulding 2
Power plant · Hydro
Key facts
Power plant · Hydroran 0% of 2025 Out of service- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1928
- Net generation, 2025
- 21 MWh
- Grid
- 60 kV to Pacific Gas & Electric Co (CISO)
- Location
- Nevada County, California
- Operated by
- Pacific Gas & Electric Co.SourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 21
MWh - Fuel burned, 2025
- 72
MMBtu - Capacity factor, 2025
- 0.1
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 21 | 72 | 0.1% | — |
| 2024 | -2 | 0 | — | — |
| 2023 | 2,247 | 7,667 | 6.9% | — |
| 2022 | 6,495 | 22,159 | 20.0% | — |
| 2021 | 6,078 | 53,755 | 18.8% | — |
| 2020 | 4,554 | 39,923 | 14.0% | — |
| 2019 | 8,166 | 72,718 | 25.2% | — |
| 2018 | 8,907 | 81,089 | 27.5% | — |
| 2017 | 5,053 | 46,553 | 15.6% | — |
| 2016 | 948 | 8,750 | 2.9% | — |
| 2015 | 6,450 | 60,109 | 19.9% | — |
| 2014 | 1,861 | 17,697 | 5.7% | — |
| 2013 | 4,736 | 45,187 | 14.6% | — |
| 2012 | 9,931 | 94,505 | 30.6% | — |
| 2011 | 17,080 | 165,948 | 52.7% | — |
| 2010 | 12,742 | 124,310 | 39.3% | — |
| 2009 | 4,343 | 42,388 | 13.4% | — |
| 2008 | 8,592 | 84,664 | 26.4% | — |
| 2007 | 9,126 | 90,201 | 28.2% | — |
| 2006 | 18,006 | 178,602 | 55.5% | — |
| 2005 | 11,472 | 114,709 | 35.4% | — |
| 2004 | 9,194 | 92,142 | 28.3% | — |
| 2003 | 10,429 | 106,803 | 32.2% | — |
| 2002 | 9,029 | 91,852 | 27.9% | — |
| 2001 | 8,199 | 84,720 | 25.3% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.