- Wind & solar
- Operating
- 10 · 100 · 1,000 MW
Map
- Wind & solar
- Operating
Sunray 2: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Sunray 2
Power plant · Solar
Key facts
Power plant · Solarran 31% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2017
- Net generation, 2025
- 54,600 MWh
- Grid
- 115 kV to Southern California Edison Co (CISO)
- Location
- San Bernardino County, California
- Operated by
- Sunray Energy 2, LLC
Operations
- Net generation, 2025
- 54,600
MWh - Fuel burned, 2025
- 186,294
MMBtu - Capacity factor, 2025
- 31.2
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 54,600 | 186,294 | 31.2% | — |
| 2024 | 57,674 | 196,784 | 32.8% | — |
| 2023 | 56,727 | 193,551 | 32.4% | — |
| 2022 | 56,290 | 192,061 | 32.1% | — |
| 2021 | 58,303 | 515,632 | 33.3% | — |
| 2020 | 58,398 | 511,975 | 33.2% | — |
| 2019 | 58,923 | 524,710 | 33.6% | — |
| 2018 | 59,838 | 544,766 | 34.2% | — |
| 2017 (7 of 12 months) | 33,317 | 306,949 | — | — |
| 2015 | 15,204 | 178,065 | 8.7% | 11,712 |
| 2014 | 11,040 | 133,433 | 6.3% | 12,086 |
| 2013 | 11,982 | 141,758 | 6.8% | 11,831 |
| 2012 | 14,708 | 168,958 | 8.4% | 11,488 |
| 2011 | 14,058 | 164,289 | 8.0% | 11,686 |
| 2010 | 13,473 | 158,848 | 7.7% | 11,790 |
| 2009 | 11,448 | 137,958 | 6.5% | 12,051 |
| 2008 | 14,885 | 156,869 | 8.5% | 10,539 |
| 2007 | 8,641 | 42,660 | 4.9% | — |
| 2006 | 9,436 | 94,853 | 5.4% | 10,052 |
| 2005 | 10,215 | 103,273 | 5.8% | 10,110 |
| 2004 | 13,696 | 138,924 | 7.8% | 10,143 |
| 2003 | 11,168 | 114,813 | 6.4% | 10,280 |
| 2002 | 12,349 | 125,580 | 7.0% | 10,169 |
| 2001 | 12,814 | 138,756 | 7.3% | 10,828 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M Preliminary Monthly Electric Generator Inventory
- Global Energy Monitor — Global Integrated Power Tracker (unit-level power plants, eight technologies, all statuses)Global Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIA Open Data bulk file — Electricity (ELEC.zip; monthly plant net generation and fuel consumption since 2001)Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)