- Clean firm
- Operating
- 10 · 100 · 1,000 MW
Map
- Clean firm
- Operating
TalenEnergy Susquehanna: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
TalenEnergy Susquehanna
Power plant · Nuclear
Key facts
Power plant · Nuclearran 84% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1983
- Net generation, 2025
- 18,566,666 MWh
- Grid
- 500 kV, 230 kV to PPL Electric Utilities Corp (PJM)
- Location
- Luzerne County, Pennsylvania
- Operated by
- TalenEnergy Susquehanna LLC
Operations
- Net generation, 2025
- 18,566,666
MWh - Fuel burned, 2025
- 193,898,872
MMBtu - Capacity factor, 2025
- 83.7
% - Heat rate, 2025
- 10,443
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 12,879,542 | 134,501,058 | — | 10,443 |
| 2025 | 18,566,666 | 193,898,872 | 83.7% | 10,443 |
| 2024 | 19,744,444 | 206,183,368 | 88.8% | 10,443 |
| 2023 | 19,000,960 | 198,599,151 | 85.7% | 10,452 |
| 2022 | 20,065,031 | 209,631,798 | 90.5% | 10,448 |
| 2021 | 19,943,546 | 207,993,495 | 89.9% | 10,429 |
| 2020 | 19,990,903 | 208,824,539 | 89.9% | 10,446 |
| 2019 | 20,919,007 | 218,428,789 | 94.3% | 10,442 |
| 2018 | 20,468,722 | 213,993,294 | 92.3% | 10,455 |
| 2017 | 20,752,565 | 217,053,727 | 93.6% | 10,459 |
| 2016 | 19,350,975 | 202,382,293 | 87.0% | 10,458 |
| 2015 | 20,591,260 | 215,353,647 | 92.8% | 10,458 |
| 2014 | 18,781,295 | 196,435,647 | 84.7% | 10,459 |
| 2013 | 18,899,063 | 197,568,800 | 85.2% | 10,454 |
| 2012 | 16,914,357 | 177,247,018 | 76.0% | 10,479 |
| 2011 | 17,363,726 | 181,798,094 | 78.3% | 10,470 |
| 2010 | 18,515,579 | 193,524,830 | 83.5% | 10,452 |
| 2009 | 19,486,657 | 204,376,057 | 87.9% | 10,488 |
| 2008 | 19,039,814 | 199,689,570 | 85.6% | 10,488 |
| 2007 | 18,237,902 | 191,224,404 | 82.2% | 10,485 |
| 2006 | 17,805,432 | 185,781,877 | 80.3% | 10,434 |
| 2005 | 18,264,359 | 190,588,586 | 82.3% | 10,435 |
| 2004 | 18,023,101 | 187,926,874 | 81.0% | 10,427 |
| 2003 | 17,959,749 | 187,158,544 | 81.0% | 10,421 |
| 2002 | 17,398,036 | 181,670,294 | 78.4% | 10,442 |
| 2001 | 17,864,666 | 186,542,842 | 80.5% | 10,442 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.