Temescal
Power plant · Hydro
Key facts
Power plant · Hydroran 7% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1983
- Net generation, 2025
- 1,882 MWh
- Grid
- 34 kV to Southern California Edison Co (CISO)
- Location
- Riverside County, California
- Operated by
- Metropolitan Water District of S CASourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 1,882
MWh - Fuel burned, 2025
- 6,422
MMBtu - Capacity factor, 2025
- 7.4
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 1,882 | 6,422 | 7.4% | — |
| 2024 | 16,799 | 57,318 | 66.0% | — |
| 2023 | 7,087 | 24,180 | 27.9% | — |
| 2022 | 8,172 | 27,881 | 32.2% | — |
| 2021 | 9,949 | 87,988 | 39.2% | — |
| 2020 | 8,408 | 73,712 | 33.0% | — |
| 2019 | 1,691 | 15,060 | 6.7% | — |
| 2018 | 4,998 | 45,502 | 19.7% | — |
| 2017 | 1,154 | 10,631 | 4.5% | — |
| 2016 | 16,278 | 150,280 | 63.9% | — |
| 2015 | 20,973 | 195,447 | 82.6% | — |
| 2014 | 16,144 | 153,528 | 63.5% | — |
| 2013 | 17,713 | 169,000 | 69.7% | — |
| 2012 | 17,151 | 163,210 | 67.3% | — |
| 2011 | 13,699 | 133,098 | 53.9% | — |
| 2010 | 19,519 | 190,429 | 76.8% | — |
| 2009 | 18,372 | 179,310 | 72.3% | — |
| 2008 | 16,451 | 162,107 | 64.6% | — |
| 2007 | 10,535 | 104,128 | 41.5% | — |
| 2006 | 6,969 | 69,125 | 27.4% | — |
| 2005 | 13,798 | 137,966 | 54.3% | — |
| 2004 | 11,427 | 114,521 | 44.9% | — |
| 2003 | 8,870 | 90,838 | 34.9% | — |
| 2002 | 16,227 | 165,077 | 63.9% | — |
| 2001 | 17,379 | 179,577 | 68.4% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
2 sourcesSources
- EIA-860M Preliminary Monthly Electric Generator Inventory
- EIA Open Data bulk file — Electricity (ELEC.zip; monthly plant net generation and fuel consumption since 2001)Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)