- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Tesoro Mandan Cogeneration Plant: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Tesoro Mandan Cogeneration Plant
Power plant · Gas, other
Key facts
Power plant · Gas, otherran 71% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1954
- Net generation, 2025
- 57,939 MWh
- Grid
- 4 kV to Montana-Dakota Utilities Co (SWPP)
- Location
- Morton County, North Dakota
- Operated by
- PAR PetroleumSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 57,939
MWh - Fuel burned, 2025
- 7,324,404
MMBtu - Capacity factor, 2025
- 71.1
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 26,760 | 5,141,880 | — | — |
| 2025 | 57,939 | 7,324,404 | 71.1% | — |
| 2024 | 41,674 | 6,061,720 | 51.0% | — |
| 2023 | 31,072 | 6,852,109 | 38.1% | — |
| 2022 | 43,409 | 6,835,536 | 53.3% | — |
| 2021 | 53,702 | 7,169,322 | 65.9% | — |
| 2020 | 57,255 | 7,305,010 | 70.1% | — |
| 2019 | 59,655 | 6,947,576 | 73.2% | — |
| 2018 | 61,318 | 7,012,868 | 75.3% | — |
| 2017 | 50,375 | 5,726,825 | 61.8% | — |
| 2016 | 60,294 | 3,764,448 | 73.8% | — |
| 2015 | 61,042 | 3,913,678 | 74.9% | — |
| 2014 | 62,038 | 3,877,877 | 76.1% | — |
| 2013 | 58,921 | 3,870,973 | 72.3% | — |
| 2012 | 57,664 | 3,911,982 | 70.6% | — |
| 2011 | 60,892 | 3,680,195 | 74.7% | — |
| 2010 | 54,185 | 3,579,464 | 66.5% | — |
| 2009 | 63,579 | 3,915,843 | 78.0% | — |
| 2008 | 61,422 | 3,179,714 | 75.2% | — |
| 2007 | 72,221 | 3,518,275 | 88.6% | — |
| 2006 | 68,764 | 3,418,929 | 84.4% | — |
| 2005 | 69,247 | 3,440,570 | 85.0% | — |
| 2004 | 69,062 | 3,713,042 | 84.5% | — |
| 2003 | 65,833 | 2,960,359 | 80.8% | — |
| 2002 (11 of 12 months) | 66,022 | 4,123,812 | — | — |
| 2001 | 81,220 | 3,562,451 | 99.7% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.