- Clean firm
- Operating
- 10 · 100 · 1,000 MW
Map
- Clean firm
- Operating
Toadtown: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Toadtown
Power plant · Hydro
Key facts
Power plant · Hydroran 11% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1986
- Net generation, 2025
- 1,779 MWh
- Grid
- 12 kV to Pacific Gas & Electric Co (CISO)
- Location
- Butte County, California
- Operated by
- Pacific Gas & Electric Co.SourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 1,779
MWh - Fuel burned, 2025
- 6,069
MMBtu - Capacity factor, 2025
- 11.3
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 1,779 | 6,069 | 11.3% | — |
| 2024 | 2,350 | 8,019 | 14.9% | — |
| 2023 | 2,519 | 8,595 | 16.0% | — |
| 2022 | 3,252 | 11,097 | 20.6% | — |
| 2021 | 1,020 | 9,020 | 6.5% | — |
| 2020 | 1,978 | 17,341 | 12.5% | — |
| 2019 | 4,332 | 38,576 | 27.5% | — |
| 2018 | 3,534 | 32,173 | 22.4% | — |
| 2017 | 3,294 | 30,349 | 20.9% | — |
| 2016 | 3,216 | 29,691 | 20.3% | — |
| 2015 | 1,875 | 17,474 | 11.9% | — |
| 2014 | 1,542 | 14,665 | 9.8% | — |
| 2013 | 3,903 | 37,238 | 24.8% | — |
| 2012 | 3,404 | 32,393 | 21.5% | — |
| 2011 | 5,852 | 56,858 | 37.1% | — |
| 2010 | 5,328 | 51,978 | 33.8% | — |
| 2009 | 3,312 | 32,326 | 21.0% | — |
| 2008 | 3,483 | 34,321 | 22.0% | — |
| 2007 | 4,024 | 39,774 | 25.5% | — |
| 2006 | 5,742 | 56,954 | 36.4% | — |
| 2005 | 5,735 | 57,344 | 36.4% | — |
| 2004 | 5,192 | 52,034 | 32.8% | — |
| 2003 | 6,524 | 66,812 | 41.4% | — |
| 2002 | 5,832 | 59,329 | 37.0% | — |
| 2001 | 4,739 | 48,968 | 30.0% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
2 sourcesSources
- EIA-860M Preliminary Monthly Electric Generator Inventory
- EIA Open Data bulk file — Electricity (ELEC.zip; monthly plant net generation and fuel consumption since 2001)Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)