- Clean firm
- Operating
- 10 · 100 · 1,000 MW
Map
- Clean firm
- Operating
Tugalo: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Tugalo
Power plant · Hydro
Key facts
Power plant · Hydroran 24% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1923
- Net generation, 2025
- 93,858 MWh
- Grid
- 115 kV to Georgia Power Co (SOCO)
- Location
- Habersham County, Georgia
- Operated by
- Georgia Power CoSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 93,858
MWh - Fuel burned, 2025
- 320,243
MMBtu - Capacity factor, 2025
- 23.9
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 93,858 | 320,243 | 23.9% | — |
| 2024 | 97,005 | 330,980 | 24.6% | — |
| 2023 | 43,577 | 148,684 | 11.1% | — |
| 2022 | 93,624 | 319,445 | 23.9% | — |
| 2021 | 135,740 | 1,200,485 | 34.6% | — |
| 2020 | 157,136 | 1,377,611 | 39.9% | — |
| 2019 | 119,650 | 1,065,482 | 30.5% | — |
| 2018 | 155,624 | 1,416,800 | 39.6% | — |
| 2017 | 74,773 | 688,885 | 19.1% | — |
| 2016 | 83,319 | 769,200 | 21.2% | — |
| 2015 | 96,649 | 900,673 | 24.6% | — |
| 2014 | 87,878 | 835,720 | 22.4% | — |
| 2013 | 159,589 | 1,522,638 | 40.7% | — |
| 2012 | 69,884 | 665,015 | 17.8% | — |
| 2011 | 75,744 | 735,929 | 19.3% | — |
| 2010 | 107,549 | 1,049,249 | 27.4% | — |
| 2009 | 131,357 | 1,282,045 | 33.5% | — |
| 2008 | 53,417 | 526,370 | 13.6% | — |
| 2007 | 50,423 | 498,380 | 12.8% | — |
| 2006 | 69,024 | 684,649 | 17.6% | — |
| 2005 | 147,514 | 1,474,992 | 37.6% | — |
| 2004 | 122,554 | 1,228,236 | 31.1% | — |
| 2003 | 147,515 | 1,510,701 | 37.6% | — |
| 2002 | 76,903 | 782,334 | 19.6% | — |
| 2001 | 55,795 | 576,530 | 14.2% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)