- Clean firm
- Operating
- 10 · 100 · 1,000 MW
Map
- Clean firm
- Operating
Turkey Point: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Turkey Point
Power plant · Nuclear
Key facts
Power plant · Nuclearran 79% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1972
- Net generation, 2025
- 20,555,599 MWh
- Grid
- 230 kV to Florida Power & Light Co (FPL)
- Location
- Miami Dade County, Florida
- Operated by
- Florida Power & Light Co
Operations
- Net generation, 2025
- 20,555,599
MWh - Fuel burned, 2025
- 192,539,836
MMBtu - Capacity factor, 2025
- 78.8
% - Heat rate, 2025
- 9,367
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 12,487,463 | 114,610,858 | — | 9,178 |
| 2025 | 20,555,599 | 192,539,836 | 78.8% | 9,367 |
| 2024 | 21,358,851 | 199,202,988 | 81.6% | 9,326 |
| 2023 | 20,061,348 | 187,397,030 | 76.9% | 9,341 |
| 2022 | 20,793,348 | 196,308,853 | 79.7% | 9,441 |
| 2021 | 19,340,939 | 183,884,211 | 74.1% | 9,508 |
| 2020 | 19,004,414 | 177,199,031 | 72.6% | 9,324 |
| 2019 | 19,270,170 | 184,153,262 | 73.9% | 9,556 |
| 2018 | 19,812,430 | 187,225,183 | 75.9% | 9,450 |
| 2017 | 18,022,697 | 171,311,945 | 69.1% | 9,505 |
| 2016 | 20,506,630 | 193,621,328 | 78.4% | 9,442 |
| 2015 | 20,337,856 | 189,569,007 | 78.0% | 9,321 |
| 2014 | 18,371,296 | 172,644,028 | 70.4% | 9,398 |
| 2013 | 17,871,733 | 166,277,942 | 68.5% | 9,304 |
| 2012 | 14,706,448 | 133,839,162 | 56.2% | 9,101 |
| 2011 | 17,017,261 | 161,329,467 | 65.2% | 9,480 |
| 2010 | 18,009,900 | 170,870,124 | 69.0% | 9,488 |
| 2009 | 18,502,138 | 172,483,306 | 70.9% | 9,322 |
| 2008 | 18,618,822 | 175,460,329 | 71.2% | 9,424 |
| 2007 | 18,425,146 | 176,904,380 | 70.6% | 9,601 |
| 2006 | 13,359,426 | 139,597,130 | 51.2% | 10,449 |
| 2005 | 13,024,814 | 134,916,835 | 49.9% | 10,358 |
| 2004 | 13,850,548 | 143,366,612 | 52.9% | 10,351 |
| 2003 | 14,232,449 | 146,338,712 | 54.5% | 10,282 |
| 2002 | 15,104,031 | 156,495,614 | 57.9% | 10,361 |
| 2001 | 14,827,758 | 153,666,536 | 56.8% | 10,363 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)