Upper Malad
Power plant · Hydro
Key facts
Power plant · Hydroran 76% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1948
- Net generation, 2025
- 55,333 MWh
- Grid
- 46 kV to Idaho Power Co (IPCO)
- Location
- Gooding County, Idaho
- Operated by
- Idaho Power CoSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 55,333
MWh - Fuel burned, 2025
- 188,796
MMBtu - Capacity factor, 2025
- 76.1
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 55,333 | 188,796 | 76.1% | — |
| 2024 | 58,274 | 198,831 | 79.9% | — |
| 2023 | 52,241 | 178,246 | 71.9% | — |
| 2022 | 54,914 | 187,367 | 75.5% | — |
| 2021 | 54,057 | 478,081 | 74.4% | — |
| 2020 | 56,453 | 494,925 | 77.4% | — |
| 2019 | 50,853 | 452,845 | 69.9% | — |
| 2018 | 36,697 | 334,089 | 50.5% | — |
| 2017 | 29,675 | 273,395 | 40.8% | — |
| 2016 | 16,427 | 151,655 | 22.5% | — |
| 2015 | 56,263 | 524,314 | 77.4% | — |
| 2014 | 55,588 | 528,643 | 76.4% | — |
| 2013 | 51,921 | 495,378 | 71.4% | — |
| 2012 | 61,465 | 584,900 | 84.3% | — |
| 2011 | 62,106 | 603,424 | 85.4% | — |
| 2010 | 61,403 | 599,047 | 84.5% | — |
| 2009 | 60,522 | 590,695 | 83.2% | — |
| 2008 | 55,558 | 547,470 | 76.2% | — |
| 2007 | 58,993 | 583,087 | 81.1% | — |
| 2006 | 60,533 | 600,426 | 83.2% | — |
| 2005 | 57,518 | 575,122 | 79.1% | — |
| 2004 | 54,027 | 541,459 | 74.1% | — |
| 2003 | 57,254 | 586,338 | 78.8% | — |
| 2002 | 58,748 | 597,643 | 80.8% | — |
| 2001 | 59,841 | 618,337 | 82.3% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.