Power plant · Gas, combustion turbine
Key facts
Power plant · Gas, combustion turbineran 0% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2002
- Net generation, 2025
- 18,330 MWh
- Grid
- 138 kV to Union Electric Co - (MO) (MISO)
- Location
- Madison County, Illinois
- Operated by
- Union Electric Co - (MO)
Operations
- Net generation, 2025
- 18,330
MWh - Fuel burned, 2025
- 216,245
MMBtu - Capacity factor, 2025
- 0.4
% - Heat rate, 2025
- 11,797
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 18,330 | 216,245 | 0.4% | 11,797 |
| 2024 | 26,835 | 307,073 | 0.5% | 11,443 |
| 2023 | 13,742 | 170,509 | 0.3% | 12,408 |
| 2022 | 21,361 | 268,522 | 0.4% | 12,571 |
| 2021 | 106,894 | 1,246,519 | 2.1% | 11,661 |
| 2020 | 64,838 | 750,410 | 1.3% | 11,574 |
| 2019 | 27,600 | 320,908 | 0.5% | 11,627 |
| 2018 | 86,592 | 994,507 | 1.7% | 11,485 |
| 2017 | 64,039 | 730,335 | 1.2% | 11,404 |
| 2016 | 77,856 | 889,275 | 1.5% | 11,422 |
| 2015 | 20,130 | 222,626 | 0.4% | 11,059 |
| 2014 | 33,921 | 387,355 | 0.7% | 11,419 |
| 2013 | 40,546 | 462,929 | 0.8% | 11,417 |
| 2012 | 188,201 | 2,107,147 | 3.7% | 11,196 |
| 2011 | 128,027 | 1,443,353 | 2.5% | 11,274 |
| 2010 | 164,539 | 1,837,207 | 3.2% | 11,166 |
| 2009 | 36,596 | 403,966 | 0.7% | 11,038 |
| 2008 | 121,769 | 1,348,241 | 2.4% | 11,072 |
| 2007 | 298,077 | 3,309,890 | 5.8% | 11,104 |
| 2006 | 119,204 | 1,300,517 | 2.3% | 10,910 |
| 2005 | 162,479 | 1,872,001 | 3.2% | 11,522 |
| 2004 | 2,365 | 50,007 | 0.1% | 21,145 |
| 2003 (11 of 12 months) | 3,775 | 39,912 | — | 10,573 |
| 2002 | 29,116 | 650,881 | 0.6% | 22,355 |
| 2001 | 29,969 | 661,196 | 0.6% | 22,063 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)