Vogtle — Power plant · Nuclear · Georgia Power Co
  • Clean firm
  • Operating
  • 10 · 100 · 1,000 MW

Power plant · Nuclear

Key facts

Power plant · Nuclearran 91% of 2025 Operating
Capacity
Capacity: sourceEIA-860M · Open licenseMW
Commissioned
1987
Net generation, 2025
37,144,415 MWh
Grid
500 kV to Georgia Power Co (SOCO)
Location
Burke County, Georgia
Operated by
Georgia Power Co

Operations

Net generation, 2025
37,144,415MWh
Fuel burned, 2025
387,913,485MMBtu
Capacity factor, 2025
91.0%
Heat rate, 2025
10,443Btu/kWh
Capacity factor % of full output, by year
Heat rate Btu per kWh, by year
Net generation, fuel burned, capacity factor and heat rate by year, newest first, as EIA's bulk electricity file states them.
YearNet generation (MWh)Fuel burned (MMBtu)Capacity factorHeat rate (Btu/kWh)
2026 (8 of 12 months)24,396,304254,838,806—10,446
202537,144,415387,913,48591.0%10,443
202433,871,811353,709,83882.8%10,443
202323,036,612240,780,02656.5%10,452
202219,515,206203,887,43747.8%10,448
202119,786,908206,359,90148.5%10,429
202018,857,818196,988,35546.1%10,446
201919,674,300205,432,00548.2%10,442
201819,959,126208,665,64848.9%10,455
201719,177,863200,583,71747.0%10,459
201619,860,229207,708,32848.5%10,458
201519,341,208202,279,98047.4%10,458
201418,060,190188,893,53544.3%10,459
201319,078,953199,350,99846.8%10,449
201219,558,197204,942,38747.8%10,479
201118,729,299195,983,38445.9%10,464
201019,610,477204,968,70848.1%10,452
200919,285,924202,270,77247.3%10,488
200817,777,553186,450,97543.5%10,488
200718,296,893191,842,92444.8%10,485
200617,947,153187,260,59844.0%10,434
200517,813,029185,878,95843.7%10,435
200419,330,957201,563,88947.2%10,427
200319,147,218199,533,15946.9%10,421
200217,057,338178,112,72441.8%10,442
200119,601,061204,674,28148.0%10,442
How these are worked out

Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.