Volta 2
Power plant · Hydro
Key facts
Power plant · Hydroran 42% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1981
- Net generation, 2025
- 3,641 MWh
- Grid
- 12 kV to Pacific Gas & Electric Co (CISO)
- Location
- Shasta County, California
- Operated by
- Pacific Gas & Electric Co.SourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 3,641
MWh - Fuel burned, 2025
- 12,423
MMBtu - Capacity factor, 2025
- 41.6
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 3,641 | 12,423 | 41.6% | — |
| 2024 | 3,137 | 10,703 | 35.7% | — |
| 2023 | 3,129 | 10,675 | 35.7% | — |
| 2022 | 2,199 | 7,500 | 25.1% | — |
| 2021 | 2,616 | 23,136 | 29.9% | — |
| 2020 | 1,425 | 12,492 | 16.2% | — |
| 2019 | 4,535 | 40,384 | 51.8% | — |
| 2018 | 5,328 | 48,505 | 60.8% | — |
| 2017 | 5,791 | 53,351 | 66.1% | — |
| 2016 | 4,786 | 44,184 | 54.5% | — |
| 2015 | 2,759 | 25,710 | 31.5% | — |
| 2014 | 3,363 | 31,981 | 38.4% | — |
| 2013 | 4,728 | 45,109 | 54.0% | — |
| 2012 | 3,006 | 28,605 | 34.2% | — |
| 2011 | 6,154 | 59,793 | 70.2% | — |
| 2010 | 4,977 | 48,557 | 56.8% | — |
| 2009 | 2,250 | 21,962 | 25.7% | — |
| 2008 | 3,752 | 36,972 | 42.7% | — |
| 2007 | 470 | 4,645 | 5.4% | — |
| 2006 | 4,457 | 44,209 | 50.9% | — |
| 2005 | 5,237 | 52,365 | 59.8% | — |
| 2004 | 5,940 | 59,531 | 67.6% | — |
| 2002 | 5,003 | 50,896 | 57.1% | — |
| 2001 | 4,684 | 48,400 | 53.5% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.