Show on map
White Bluff — Power plant · Coal · Entergy Arkansas LLC
  • Combustion
  • Operating
  • 10 · 100 · 1,000 MW

White Bluff

Power plant · Coal

Key facts

Power plant · Coalran 25% of 2025 Operating
Capacity
Capacity: sourceEIA-860M · Open licenseMW
Commissioned
1980
Net generation, 2025
3,871,368 MWh
Grid
500 kV to Entergy Arkansas Inc (MISO)
Location
Jefferson County, Arkansas

Operations

Net generation, 2025
3,871,368MWh
Fuel burned, 2025
42,551,191MMBtu
Capacity factor, 2025
24.6%
Heat rate, 2025
10,991Btu/kWh
Capacity factor % of full output, by year
Heat rate Btu per kWh, by year
Net generation, fuel burned, capacity factor and heat rate by year, newest first, as EIA's bulk electricity file states them.
YearNet generation (MWh)Fuel burned (MMBtu)Capacity factorHeat rate (Btu/kWh)
2026 (8 of 12 months)1,665,56418,599,463—11,167
20253,871,36842,551,19124.6%10,991
20242,045,19023,218,23612.9%11,353
20233,560,85339,567,19222.6%11,112
20225,278,44056,472,56633.5%10,699
20217,060,25868,343,30544.8%9,680
20203,954,90842,069,66525.0%10,637
2019 (11 of 12 months)6,743,33269,837,092—10,356
20188,251,96785,153,53852.3%10,319
20178,007,03279,922,40450.8%9,982
20165,697,53860,005,10336.0%10,532
20156,223,12965,033,62239.5%10,450
201410,526,995107,760,63966.8%10,237
201310,561,665109,629,33367.0%10,380
20129,506,21799,856,48660.1%10,504
201110,402,696106,871,23266.0%10,273
201010,958,990112,042,57269.5%10,224
200910,802,906110,284,18668.5%10,209
200811,112,298114,072,17970.3%10,265
20079,994,547105,924,67263.4%10,598
20069,654,935101,711,56861.2%10,535
20059,261,32098,030,31358.7%10,585
200410,951,095114,729,71269.3%10,477
20039,895,175104,219,34762.7%10,532
20028,850,93594,643,63556.1%10,693
20019,651,935102,890,64261.2%10,660
How these are worked out

Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.

Sources

3 sources

Sources EIA-860M · GEM · EIA

Sources

  • EIA-860MOpen license · retrieved Nov 4, 2026
  • GEMOpen license, with credit · retrieved Oct 26, 2026Global Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
  • EIAOpen license · retrieved Nov 1, 2026Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)

Every source and license · Attribution

View at source