White Rapids
Power plant · Hydro
Key facts
Power plant · Hydroran 47% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1927
- Net generation, 2025
- 32,651 MWh
- Grid
- 138 kV to American Transmission Co (MISO)
- Location
- Menominee County, Michigan
- Operated by
- Wisconsin Electric Power CoSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 32,651
MWh - Fuel burned, 2025
- 111,404
MMBtu - Capacity factor, 2025
- 46.6
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 32,651 | 111,404 | 46.6% | — |
| 2024 | 29,789 | 101,638 | 42.4% | — |
| 2023 | 29,795 | 101,659 | 42.5% | — |
| 2022 | 31,672 | 108,065 | 45.2% | — |
| 2021 | 31,787 | 281,124 | 45.4% | — |
| 2020 | 43,154 | 378,330 | 61.4% | — |
| 2019 | 38,412 | 342,058 | 54.8% | — |
| 2018 | 39,099 | 355,958 | 55.8% | — |
| 2017 | 48,395 | 445,863 | 69.1% | — |
| 2016 | 40,460 | 373,526 | 57.6% | — |
| 2015 | 37,770 | 351,977 | 53.9% | — |
| 2014 | 36,848 | 350,425 | 52.6% | — |
| 2013 | 31,325 | 298,873 | 44.7% | — |
| 2012 | 24,623 | 234,313 | 35.0% | — |
| 2011 | 31,238 | 303,508 | 44.6% | — |
| 2010 | 29,425 | 287,071 | 42.0% | — |
| 2009 | 24,071 | 234,931 | 34.4% | — |
| 2008 | 22,938 | 226,031 | 32.6% | — |
| 2007 | 23,851 | 235,744 | 34.0% | — |
| 2006 | 27,922 | 276,958 | 39.8% | — |
| 2005 | 28,836 | 288,331 | 41.1% | — |
| 2004 | 33,370 | 334,434 | 47.5% | — |
| 2003 | 30,902 | 316,467 | 44.1% | — |
| 2002 | 36,639 | 372,729 | 52.3% | — |
| 2001 | 30,638 | 316,582 | 43.7% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.