- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
York Energy Center: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
York Energy Center
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 69% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2011
- Net generation, 2025
- 8,785,592 MWh
- Grid
- 500 kV to PECO Energy Co (PJM)
- Location
- York County, Pennsylvania
- Operated by
- Calpine Mid-Merit LLC
Operations
- Net generation, 2025
- 8,785,592
MWh - Fuel burned, 2025
- 64,684,208
MMBtu - Capacity factor, 2025
- 69.2
% - Heat rate, 2025
- 7,362
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 6,251,137 | 46,575,879 | — | 7,451 |
| 2025 | 8,785,592 | 64,684,208 | 69.2% | 7,362 |
| 2024 | 9,155,267 | 67,079,989 | 71.9% | 7,327 |
| 2023 | 8,631,405 | 63,461,793 | 68.0% | 7,352 |
| 2022 | 7,125,250 | 51,914,873 | 56.1% | 7,286 |
| 2021 | 7,648,984 | 55,575,467 | 60.2% | 7,266 |
| 2020 | 8,565,788 | 61,822,149 | 67.3% | 7,217 |
| 2019 | 5,340,573 | 38,408,731 | 42.1% | 7,192 |
| 2018 | 1,838,910 | 14,651,058 | 14.5% | 7,967 |
| 2017 | 1,590,271 | 12,731,791 | 12.5% | 8,006 |
| 2016 | 1,552,401 | 12,462,779 | 12.2% | 8,028 |
| 2015 | 1,976,570 | 15,617,083 | 15.6% | 7,901 |
| 2014 | 2,537,264 | 20,087,463 | 20.0% | 7,917 |
| 2013 | 2,018,737 | 15,932,795 | 15.9% | 7,892 |
| 2012 | 3,483,387 | 27,113,010 | 27.4% | 7,784 |
| 2011 (10 of 12 months) | 1,294,289 | 10,197,595 | — | 7,879 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)