Show on map
Caledonia — Power plant · Gas, combined cycle · Tennessee Valley Authority
  • Combustion
  • Operating
  • 10 · 100 · 1,000 MW

Power plant · Gas, combined cycle

Key facts

Power plant · Gas, combined cycleran 75% of 2025 Operating
Capacity
Capacity: sourceEIA-860M · Open licenseMW
Commissioned
2003
Net generation, 2025
5,246,915 MWh
Grid
500 kV to Tennessee Valley Authority (TVA)
Location
Lowndes County, Mississippi

Operations

Net generation, 2025
5,246,915MWh
Fuel burned, 2025
36,666,571MMBtu
Capacity factor, 2025
74.8%
Heat rate, 2025
6,988Btu/kWh
Capacity factor % of full output, by year
Heat rate Btu per kWh, by year
Net generation, fuel burned, capacity factor and heat rate by year, newest first, as EIA's bulk electricity file states them.
YearNet generation (MWh)Fuel burned (MMBtu)Capacity factorHeat rate (Btu/kWh)
2026 (8 of 12 months)3,270,56322,830,183—6,980
20255,246,91536,666,57174.8%6,988
20245,125,48135,785,84872.9%6,982
20233,897,79727,162,47355.5%6,969
20224,662,35932,286,75166.5%6,925
20214,359,95730,221,67262.1%6,932
20204,515,32131,120,94764.2%6,892
20193,958,08327,410,71456.4%6,925
20184,064,34528,636,42757.9%7,046
20174,340,82631,048,83961.9%7,153
20164,773,39634,569,85967.8%7,242
20153,413,50924,722,70248.6%7,243
20142,717,82919,698,99638.7%7,248
20133,277,21723,885,52446.7%7,288
20124,510,50033,111,66064.1%7,341
20113,728,96227,195,13553.1%7,293
20104,164,93329,791,16459.4%7,153
20093,627,79424,978,13651.7%6,885
20082,656,95818,523,75737.8%6,972
20072,096,52414,820,52229.9%7,069
2006949,5006,593,00413.5%6,944
20051,076,5777,648,27115.3%7,104
20041,389,2369,903,21819.7%7,128
2003 (10 of 12 months)446,5754,017,922—8,997
How these are worked out

Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.

Sources

3 sources

Sources EIA-860M · GEM · EIA

Sources

  • EIA-860MOpen license · retrieved Nov 4, 2026
  • GEMOpen license, with credit · retrieved Oct 26, 2026Global Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.