Coyote Springs II
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 86% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2003
- Net generation, 2025
- 2,159,888 MWh
- Grid
- 500 kV to Avista Corp (BPAT)
- Location
- Morrow County, Oregon
- Operated by
- Avista CorpSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 2,159,888
MWh - Fuel burned, 2025
- 15,043,500
MMBtu - Capacity factor, 2025
- 85.9
% - Heat rate, 2025
- 6,965
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 959,636 | 6,709,454 | — | 6,992 |
| 2025 | 2,159,888 | 15,043,500 | 85.9% | 6,965 |
| 2024 | 2,325,857 | 16,092,153 | 92.3% | 6,919 |
| 2023 | 2,263,061 | 15,602,257 | 90.0% | 6,894 |
| 2022 | 1,844,243 | 12,833,774 | 73.4% | 6,959 |
| 2021 | 1,533,635 | 10,544,313 | 61.0% | 6,875 |
| 2020 | 1,767,332 | 12,135,469 | 70.1% | 6,866 |
| 2019 | 1,890,016 | 13,014,728 | 75.2% | 6,886 |
| 2018 | 1,495,191 | 10,453,023 | 59.5% | 6,991 |
| 2017 | 1,659,029 | 11,588,075 | 66.0% | 6,985 |
| 2016 | 1,765,406 | 12,273,305 | 70.0% | 6,952 |
| 2015 | 1,891,951 | 13,259,821 | 75.2% | 7,008 |
| 2014 | 1,493,933 | 10,414,002 | 59.4% | 6,971 |
| 2013 | 1,796,280 | 12,585,102 | 71.5% | 7,006 |
| 2012 | 1,142,118 | 7,933,186 | 45.3% | 6,946 |
| 2011 | 705,062 | 4,962,799 | 28.0% | 7,039 |
| 2010 | 1,661,182 | 11,581,370 | 66.1% | 6,972 |
| 2009 | 1,559,367 | 10,913,269 | 62.0% | 6,998 |
| 2008 | 1,696,319 | 11,841,987 | 67.3% | 6,981 |
| 2007 | 1,622,778 | 11,401,274 | 64.5% | 7,026 |
| 2006 | 1,459,337 | 10,232,672 | 58.1% | 7,012 |
| 2005 | 1,583,391 | 10,917,594 | 63.0% | 6,895 |
| 2004 | 660,133 | 4,400,370 | 26.2% | 6,666 |
| 2003 (6 of 12 months) | 714,581 | 4,970,103 | — | 6,955 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.