Power plant · Gas, combustion turbine
Key facts
Power plant · Gas, combustion turbineran 12% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2000
- Net generation, 2025
- 145,140 MWh
- Grid
- 120 kV to ITC Transmission (MISO)
- Location
- Wayne County, Michigan
- Operated by
- DTE Electric Company
Operations
- Net generation, 2025
- 145,140
MWh - Fuel burned, 2025
- 1,759,393
MMBtu - Capacity factor, 2025
- 11.7
% - Heat rate, 2025
- 12,122
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 145,140 | 1,759,393 | 11.7% | 12,122 |
| 2024 | 90,867 | 1,042,799 | 7.3% | 11,476 |
| 2023 | 21,398 | 259,290 | 1.7% | 12,118 |
| 2022 | 42,531 | 527,955 | 3.4% | 12,413 |
| 2021 | 22,009 | 291,337 | 1.8% | 13,237 |
| 2020 | 34,746 | 421,294 | 2.8% | 12,125 |
| 2019 | 10,722 | 150,275 | 0.9% | 14,016 |
| 2018 | 16,136 | 215,048 | 1.3% | 13,327 |
| 2017 | 26,823 | 351,856 | 2.1% | 13,118 |
| 2016 | 29,244 | 391,850 | 2.3% | 13,399 |
| 2015 | 9,242 | 142,543 | 0.7% | 15,423 |
| 2014 | 12,639 | 180,337 | 1.0% | 14,268 |
| 2013 | 13,019 | 189,721 | 1.1% | 14,573 |
| 2012 | 44,519 | 565,126 | 3.6% | 12,694 |
| 2011 | 18,347 | 191,382 | 1.5% | 10,431 |
| 2010 | 30,252 | 370,428 | 2.4% | 12,245 |
| 2009 | 2,784 | 46,569 | 0.2% | 16,727 |
| 2008 | 6,935 | 111,053 | 0.6% | 16,013 |
| 2007 | 31,745 | 427,165 | 2.5% | 13,456 |
| 2006 | 29,057 | 385,924 | 2.3% | 13,282 |
| 2005 | 57,355 | 733,163 | 4.6% | 12,783 |
| 2004 | 26,614 | 314,861 | 2.1% | 11,831 |
| 2003 | 36,176 | 422,042 | 2.9% | 11,666 |
| 2002 | 63,809 | 766,465 | 5.1% | 12,012 |
| 2001 | 28,349 | 370,753 | 2.3% | 13,078 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.