- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Drews Generating Facility: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Drews Generating Facility
Power plant · Gas, combustion turbine
Key facts
Power plant · Gas, combustion turbineran 0% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2001
- Net generation, 2025
- 570 MWh
- Grid
- 66 kV to City of Colton - (CA) (CISO)
- Location
- San Bernardino County, California
- Operated by
- Colton Power LPSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 570
MWh - Fuel burned, 2025
- 8,647
MMBtu - Capacity factor, 2025
- 0.1
% - Heat rate, 2025
- 15,170
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 570 | 8,647 | 0.1% | 15,170 |
| 2024 | 1,017 | 17,795 | 0.3% | 17,498 |
| 2023 | 606 | 14,873 | 0.1% | 24,543 |
| 2022 | 843 | 14,706 | 0.2% | 17,445 |
| 2021 | 268 | 3,485 | 0.1% | 13,004 |
| 2020 | 615 | 9,817 | 0.2% | 15,963 |
| 2019 | 414 | 6,274 | 0.1% | 15,155 |
| 2018 | 777 | 16,686 | 0.2% | 21,475 |
| 2017 | 1,276 | 22,551 | 0.3% | 17,673 |
| 2016 | 1,515 | 22,597 | 0.4% | 14,916 |
| 2015 | 1,655 | 14,273 | 0.4% | 8,624 |
| 2014 | 1,198 | 18,670 | 0.3% | 15,584 |
| 2013 | 1,812 | 45,059 | 0.5% | 24,867 |
| 2012 | 2,008 | 43,954 | 0.5% | 21,889 |
| 2011 | 60 | 972 | 0.0% | 16,200 |
| 2010 | 1,506 | 28,873 | 0.4% | 19,172 |
| 2009 | 420 | 8,014 | 0.1% | 19,081 |
| 2008 | 1,116 | 21,253 | 0.3% | 19,044 |
| 2007 | 1,669 | 32,386 | 0.4% | 19,404 |
| 2006 | 1,895 | 36,954 | 0.5% | 19,501 |
| 2005 | 1,249 | 17,525 | 0.3% | 14,031 |
| 2004 | 5,119 | 71,387 | 1.3% | 13,946 |
| 2003 | 6,790 | 89,350 | 1.7% | 13,158 |
| 2002 | 18,212 | 239,176 | 4.6% | 13,133 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.