- Wind & solar
- Operating
- 10 · 100 · 1,000 MW
Map
- Wind & solar
- Operating
Golden Springs Building C-1: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Golden Springs Building C-1
Power plant · Solar
Key facts
Power plant · Solarran 13% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2012
- Net generation, 2025
- 1,410 MWh
- Grid
- 12 kV to Southern California Edison Co (CISO)
- Location
- Los Angeles County, California
- Operated by
- Golden Springs Development Company LLCSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 1,410
MWh - Fuel burned, 2025
- 4,811
MMBtu - Capacity factor, 2025
- 13.4
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 1,410 | 4,811 | 13.4% | — |
| 2024 | 1,334 | 4,552 | 12.7% | — |
| 2023 | 1,749 | 5,967 | 16.6% | — |
| 2022 | 1,890 | 6,448 | 18.0% | — |
| 2021 | 1,730 | 15,300 | 16.5% | — |
| 2020 | 1,753 | 15,368 | 16.6% | — |
| 2019 | 1,631 | 14,524 | 15.5% | — |
| 2018 | 1,796 | 16,350 | 17.1% | — |
| 2017 | 1,894 | 17,449 | 18.0% | — |
| 2016 | 1,819 | 16,794 | 17.3% | — |
| 2015 | 1,883 | 17,548 | 17.9% | — |
| 2014 | 1,895 | 18,021 | 18.0% | — |
| 2013 | 2,012 | 19,198 | 19.1% | — |
| 2012 (11 of 12 months) | 1,725 | 16,416 | — | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)