- Bioenergy
- Operating
- 10 · 100 · 1,000 MW
Map
- Bioenergy
- Operating
Greene Valley Gas Recovery: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Greene Valley Gas Recovery
Power plant · Biomass
Key facts
Power plant · Biomassran 39% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1996
- Net generation, 2025
- 22,352 MWh
- Grid
- 12 kV to Commonwealth Edison Co (PJM)
- Location
- DuPage County, Illinois
- Operated by
- WM Illinois Renewable Energy LLC
Operations
- Net generation, 2025
- 22,352
MWh - Fuel burned, 2025
- 477,194
MMBtu - Capacity factor, 2025
- 38.7
% - Heat rate, 2025
- 21,349
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 22,352 | 477,194 | 38.7% | 21,349 |
| 2024 | 22,518 | 612,670 | 38.8% | 27,208 |
| 2023 | 26,082 | 580,583 | 45.1% | 22,260 |
| 2022 | 26,279 | 580,065 | 45.5% | 22,073 |
| 2021 | 29,868 | 619,941 | 51.7% | 20,756 |
| 2020 | 33,849 | 661,817 | 58.4% | 19,552 |
| 2019 | 35,393 | 682,579 | 61.2% | 19,286 |
| 2018 | 36,013 | 680,114 | 62.3% | 18,885 |
| 2017 | 37,758 | 473,595 | 65.3% | 12,543 |
| 2016 | 39,834 | 738,100 | 68.7% | 18,529 |
| 2015 | 39,678 | 734,535 | 68.6% | 18,512 |
| 2014 | 42,749 | 781,927 | 73.9% | 18,291 |
| 2013 | 42,040 | 762,725 | 72.7% | 18,143 |
| 2012 | 43,072 | 791,173 | 74.3% | 18,369 |
| 2011 | 46,053 | 801,351 | 79.7% | 17,401 |
| 2010 | 46,598 | 822,142 | 80.6% | 17,643 |
| 2009 | 49,243 | 872,314 | 85.2% | 17,714 |
| 2008 | 49,444 | 875,923 | 85.3% | 17,716 |
| 2007 | 49,642 | 891,328 | 85.9% | 17,955 |
| 2006 | 48,808 | 888,754 | 84.4% | 18,209 |
| 2005 | 46,606 | 849,866 | 80.6% | 18,235 |
| 2004 | 49,893 | 985,020 | 86.1% | 19,743 |
| 2003 | 53,046 | 931,025 | 91.8% | 17,551 |
| 2002 | 61,662 | 1,109,557 | — | 17,994 |
| 2001 | 64,196 | 1,128,020 | — | 17,572 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.