GRS CMS — Power plant · Biomass · Gas Recovery Systems Inc
  • Bioenergy
  • Operating
  • 10 · 100 · 1,000 MW

Power plant · Biomass

Key facts

Power plant · Biomassran 9% of 2025 Operating
Capacity
Capacity: sourceEIA-860M · Open licenseMW
Commissioned
1999
Net generation, 2025
4,272 MWh
Grid
13 kV to City of Concord - (NC) (DUK)
Location
Cabarrus County, North Carolina
Operated by
Gas Recovery Systems IncSourceEIA-860M Preliminary Monthly Electric Generator Inventory

Operations

Net generation, 2025
4,272MWh
Fuel burned, 2025
69,177MMBtu
Capacity factor, 2025
9.2%
Heat rate, 2025
16,193Btu/kWh
Capacity factor % of full output, by year
Heat rate Btu per kWh, by year
Net generation, fuel burned, capacity factor and heat rate by year, newest first, as EIA's bulk electricity file states them.
YearNet generation (MWh)Fuel burned (MMBtu)Capacity factorHeat rate (Btu/kWh)
20254,27269,1779.2%16,193
20246109,1811.3%15,051
202316,767252,62036.1%15,066
20223,55053,5367.6%15,081
202120,130311,44143.4%15,472
20207,601100,63616.3%13,240
201925,653418,04155.2%16,296
201825,701406,20355.4%15,805
201728,303432,20861.0%15,271
201629,909463,18164.2%15,486
201527,870438,78560.0%15,744
201428,400459,99561.2%16,197
201324,190417,77152.1%17,270
201227,776438,82359.7%15,799
201126,858431,36257.9%16,061
201024,546358,44352.9%14,603
200925,808626,41055.6%24,272
200825,117413,25853.9%16,453
200721,696346,31246.7%15,962
200625,389417,43154.7%16,441
200525,707427,58355.4%16,633
200430,670502,79865.9%16,394
200332,777468,80870.6%14,303
200227,721424,66759.7%15,319
200119,362602,79841.7%—
How these are worked out

Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.

Sources

2 sources

Sources EIA-860M · EIA

Sources

  • EIA-860MOpen license · retrieved Nov 4, 2026
  • EIAOpen license · retrieved Nov 1, 2026Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)

Every source and license · Attribution

View at source