- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
H Allen Franklin Combined Cycle: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
H Allen Franklin Combined Cycle
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 69% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2002
- Net generation, 2025
- 12,061,177 MWh
- Grid
- 230 kV to Georgia Power Co (SOCO)
- Location
- Lee County, Alabama
- Operated by
- Southern Power Co
Operations
- Net generation, 2025
- 12,061,177
MWh - Fuel burned, 2025
- 84,506,250
MMBtu - Capacity factor, 2025
- 69.0
% - Heat rate, 2025
- 7,006
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 8,366,504 | 58,267,743 | — | 6,964 |
| 2025 | 12,061,177 | 84,506,250 | 69.0% | 7,006 |
| 2024 | 11,738,168 | 82,035,139 | 67.0% | 6,989 |
| 2023 | 13,682,165 | 95,143,646 | 78.3% | 6,954 |
| 2022 | 11,641,023 | 83,067,578 | 66.6% | 7,136 |
| 2021 | 11,356,994 | 79,712,971 | 65.0% | 7,019 |
| 2020 | 12,637,167 | 88,964,542 | 72.1% | 7,040 |
| 2019 | 12,462,636 | 87,912,005 | 71.3% | 7,054 |
| 2018 | 12,248,562 | 86,046,083 | 70.1% | 7,025 |
| 2017 | 12,465,364 | 87,394,974 | 71.3% | 7,011 |
| 2016 | 11,670,861 | 82,708,814 | 66.6% | 7,087 |
| 2015 | 10,743,084 | 76,381,178 | 61.5% | 7,110 |
| 2014 | 10,167,617 | 72,418,827 | 58.2% | 7,122 |
| 2013 | 8,950,998 | 63,432,921 | 51.2% | 7,087 |
| 2012 | 10,863,076 | 77,080,296 | 62.0% | 7,096 |
| 2011 | 9,591,803 | 68,186,737 | 54.9% | 7,109 |
| 2010 | 7,713,188 | 55,045,897 | 44.1% | 7,137 |
| 2009 | 7,254,275 | 51,496,285 | 41.5% | 7,099 |
| 2008 | 5,118,213 | 36,549,967 | 29.2% | 7,141 |
| 2007 | 3,716,876 | 26,995,179 | 21.3% | 7,263 |
| 2006 | 2,701,133 | 19,536,969 | 15.4% | 7,233 |
| 2005 | 1,886,431 | 13,898,473 | 10.8% | 7,368 |
| 2004 | 2,518,886 | 18,155,320 | 14.4% | 7,208 |
| 2003 | 1,600,305 | 11,743,343 | 9.2% | 7,338 |
| 2002 (7 of 12 months) | 1,019,310 | 7,500,414 | — | 7,358 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)