- Combustion
- Retired
- 10 · 100 · 1,000 MW
Map
- Combustion
- Retired
Junction: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Junction
Power plant · Oil
Key facts
Power plant · Oilran 1% of 2011 Retired- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1965
- Net generation, 2011
- 1,766 MWh
- Location
- Pierce County, Wisconsin
- Operated by
- City of River FallsSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Output
- Gas
- Oil
Details
Who’s behind it
No companies named in filings yet.
Interested in this project?
Set an alert Book a call Join the beta
Our team gets you what you need.
Beta: private project space · data room · readiness check
- Technology
- Oil source: “Petroleum Liquids”
- Age
- 61 years since 1965
Retirement
EIA-860M September 2026StatusEvery generator EIA lists at this plant has retired. As of EIA-860M for September 2026.- Retired
- December 2011
- First unit retired
- May 2003
- Capacity retired
- 20.1 MW
- Generators retired
- 6
| Generator | Technology | Nameplate | State | Date |
|---|---|---|---|---|
| 8 | Petroleum Liquids | 0.3 MW | Retired | May 2003 |
| 10 | Petroleum Liquids | 3 MW | Retired | December 2011 |
| 5 | Petroleum Liquids | 2.8 MW | Retired | December 2011 |
| 6 | Petroleum Liquids | 2 MW | Retired | December 2011 |
| 7 | Petroleum Liquids | 6 MW | Retired | December 2011 |
| 9 | Petroleum Liquids | 6 MW | Retired | December 2011 |
Grid
Not in EIA-860Grid fieldsEIA-860 states no grid voltage or transmission owner for this plant: its annual file lists plants with a generator in the report year, so a plant that retired earlier is not in it.Transmission lines within 25 km (4)
Can the connection be reused?
A plant that retires usually leaves its substation, transmission connection and interconnection agreement behind, and those may be reusable by a new project at the same site. FERC Order No. 845 lets an interconnection customer use surplus interconnection service at an existing site, and some transmission providers' tariffs let a replacement resource take over a retiring unit's interconnection service, usually within a set time after the retirement. Whether any such right still exists here, who holds it and on what terms depends on the owner, the transmission provider and timing; this page does not establish any of that.
Timeline
- Stated Units 10, 5, 6, 7, 9 scheduled to retire, 19.8 MW · EIA-860M
- Stated Unit 8 scheduled to retire, 0.3 MW · EIA-860M
- In service · EIA-860M
Sources
4 sourcesSources EIA-860M · LBNL · EIA · EIA-860M Preliminary Monthly Electric Generator Inventory
Sources
- EIA-860M Preliminary Monthly Electric Generator Inventory
- LBNL — A Harmonized Geospatial Dataset of U.S. Transmission Lines: Linking FERC Form 1 and HIFLD, 1994-2024 (OEDI submission 8742)Yin, Nait Belaid & Heleno (2026), Lawrence Berkeley National Laboratory, OEDI, CC BY 4.0: A Harmonized Geospatial Dataset of U.S. Transmission Lines: Linking FERC Form 1 and HIFLD, 1994-2024. Modified by Inframation: HIFLD-side fields only, names re-cased, coordinates rounded.
- EIA Open Data bulk file — Electricity (ELEC.zip; monthly plant net generation and fuel consumption since 2001)Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)
- EIA-860M Preliminary Monthly Electric Generator Inventory