- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Masspower: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Masspower
Power plant · Gas, combined cycle
Operations
- Net generation, 2025
- 441,701
MWh - Fuel burned, 2025
- 3,997,318
MMBtu - Capacity factor, 2025
- 19.3
% - Heat rate, 2025
- 9,050
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 441,701 | 3,997,318 | 19.3% | 9,050 |
| 2024 | 475,710 | 4,090,340 | 20.8% | 8,598 |
| 2023 | 609,145 | 5,322,667 | 26.7% | 8,738 |
| 2022 | 233,904 | 2,063,245 | 10.2% | 8,821 |
| 2021 | 256,254 | 2,377,443 | 11.2% | 9,278 |
| 2020 | 352,632 | 3,084,003 | 15.4% | 8,746 |
| 2019 | 282,447 | 2,450,963 | 12.4% | 8,678 |
| 2018 | 498,909 | 4,386,719 | 21.8% | 8,793 |
| 2017 | 625,242 | 5,396,609 | 27.4% | 8,631 |
| 2016 | 678,568 | 5,859,740 | 29.6% | 8,635 |
| 2015 | 876,022 | 7,509,872 | 38.3% | 8,573 |
| 2014 | 781,932 | 6,677,360 | 34.2% | 8,540 |
| 2013 | 716,500 | 6,161,976 | 31.4% | 8,600 |
| 2012 | 870,195 | 7,463,995 | 38.0% | 8,577 |
| 2011 | 840,417 | 7,155,719 | 36.8% | 8,514 |
| 2010 | 555,613 | 4,749,210 | 24.3% | 8,548 |
| 2009 | 181,031 | 1,555,412 | 7.9% | 8,592 |
| 2008 | 241,526 | 2,120,722 | 10.5% | 8,780 |
| 2007 | 376,398 | 3,321,648 | 16.5% | 8,825 |
| 2006 | 359,193 | 3,199,577 | 15.7% | 8,908 |
| 2005 | 841,508 | 7,540,737 | 36.8% | 8,961 |
| 2004 | 1,240,552 | 11,156,612 | 54.1% | 8,993 |
| 2003 | 1,642,081 | 14,342,883 | 71.9% | 8,735 |
| 2002 | 1,518,043 | 12,957,992 | 66.4% | 8,536 |
| 2001 | 1,328,005 | 11,911,574 | 58.1% | 8,970 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)