- Bioenergy
- Operating
- 10 · 100 · 1,000 MW
Map
- Bioenergy
- Operating
Norther Tier Landfill: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Norther Tier Landfill
Power plant · Biomass
Key facts
Power plant · Biomassran 60% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2009
- Net generation, 2025
- 8,451 MWh
- Grid
- 34 kV to Pennsylvania Electric Co (PJM)
- Location
- Bradford County, Pennsylvania
- Operated by
- NextEra Renewable Fuels, LLCSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 8,451
MWh - Fuel burned, 2025
- 96,524
MMBtu - Capacity factor, 2025
- 60.3
% - Heat rate, 2025
- 11,422
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 8,451 | 96,524 | 60.3% | 11,422 |
| 2024 | 6,155 | 75,119 | 43.8% | 12,204 |
| 2023 | 8,842 | 107,738 | 63.1% | 12,185 |
| 2022 | 8,949 | 106,183 | 63.8% | 11,865 |
| 2021 | 10,045 | 113,403 | 71.7% | 11,290 |
| 2020 | 11,897 | 132,247 | 84.7% | 11,116 |
| 2019 | 12,052 | 138,816 | 86.0% | 11,518 |
| 2018 | 12,116 | 131,719 | 86.4% | 10,872 |
| 2017 | 12,110 | 131,042 | 86.4% | 10,821 |
| 2016 | 11,447 | 129,882 | 81.5% | 11,346 |
| 2015 | 9,452 | 106,749 | 67.4% | 11,294 |
| 2014 | 10,466 | 116,031 | 74.7% | 11,086 |
| 2013 | 10,180 | 117,304 | 72.6% | 11,523 |
| 2012 | 11,605 | 131,099 | 82.6% | 11,297 |
| 2011 | 11,033 | 129,258 | 78.7% | 11,716 |
| 2010 | 11,713 | 137,353 | 83.6% | 11,726 |
| 2009 | 10,712 | 121,842 | 76.4% | 11,374 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.