Pirkey
Power plant · Coal
Key facts
Power plant · Coalran 47% of 2022 Retired- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1985
- Net generation, 2022
- 2,957,777 MWh
- Grid
- 138 kV to Southwestern Electric Power Co (SWPP)
- Location
- Harrison County, Texas
- Operated by
- Southwestern Electric Power Co
Operations
- Net generation, 2022
- 2,957,777
MWh - Fuel burned, 2022
- 32,365,719
MMBtu - Capacity factor, 2022
- 46.8
% - Heat rate, 2022
- 10,943
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2023 (3 of 12 months) | 871,741 | 9,587,369 | — | 10,998 |
| 2022 | 2,957,777 | 32,365,719 | 46.8% | 10,943 |
| 2021 | 2,689,736 | 29,950,268 | 42.6% | 11,135 |
| 2020 | 2,185,552 | 24,784,428 | 34.5% | 11,340 |
| 2019 | 3,071,153 | 33,006,086 | 48.6% | 10,747 |
| 2018 | 4,585,248 | 47,793,762 | 72.6% | 10,423 |
| 2017 | 4,295,786 | 45,288,924 | 68.0% | 10,543 |
| 2016 | 5,087,735 | 53,226,030 | 80.3% | 10,462 |
| 2015 | 4,583,206 | 48,846,431 | 72.6% | 10,658 |
| 2014 | 5,084,652 | 53,804,346 | 80.5% | 10,582 |
| 2013 | 4,936,145 | 53,090,649 | 78.1% | 10,756 |
| 2012 | 4,323,455 | 46,510,847 | 68.3% | 10,758 |
| 2011 | 4,721,914 | 50,787,426 | 74.8% | 10,756 |
| 2010 | 4,847,270 | 52,023,179 | 76.8% | 10,732 |
| 2009 | 3,462,031 | 38,260,810 | 54.8% | 11,052 |
| 2008 | 4,693,686 | 51,373,867 | 74.1% | 10,945 |
| 2007 | 4,824,785 | 53,708,525 | 76.4% | 11,132 |
| 2006 | 4,501,460 | 48,323,014 | 71.3% | 10,735 |
| 2005 | 4,993,144 | 53,392,245 | 79.1% | 10,693 |
| 2004 | 5,117,188 | 54,854,138 | 80.8% | 10,720 |
| 2003 | 4,770,129 | 50,665,106 | 75.5% | 10,621 |
| 2002 | 4,504,102 | 49,844,516 | 71.3% | 11,066 |
| 2001 | 3,681,203 | 40,800,215 | 58.3% | 11,083 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.