- Clean firm
- Operating
- 10 · 100 · 1,000 MW
Map
- Clean firm
- Operating
Prospect 2: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Prospect 2
Power plant · Hydro
Key facts
Power plant · Hydroran 64% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1928
- Net generation, 2025
- 180,089 MWh
- Grid
- 69 kV to PacifiCorp (PACW)
- Location
- Jackson County, Oregon
- Operated by
- PacifiCorpSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 180,089
MWh - Fuel burned, 2025
- 614,464
MMBtu - Capacity factor, 2025
- 64.2
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 180,089 | 614,464 | 64.2% | — |
| 2024 | 193,137 | 658,985 | 68.7% | — |
| 2023 | 163,295 | 557,163 | 58.2% | — |
| 2022 | 161,545 | 551,192 | 57.6% | — |
| 2021 | 153,144 | 1,354,405 | 54.6% | — |
| 2020 | 175,890 | 1,542,027 | 62.6% | — |
| 2019 | 190,315 | 1,694,756 | 67.9% | — |
| 2018 | 199,202 | 1,813,533 | 71.1% | — |
| 2017 | 256,205 | 2,360,417 | 91.4% | — |
| 2016 | 239,892 | 2,214,683 | 85.3% | — |
| 2015 | 166,763 | 1,554,064 | 59.5% | — |
| 2014 | 206,474 | 1,963,568 | 73.7% | — |
| 2013 | 215,139 | 2,052,641 | 76.8% | — |
| 2012 | 238,047 | 2,265,256 | 84.7% | — |
| 2011 | 251,221 | 2,440,865 | 89.6% | — |
| 2010 | 225,131 | 2,196,378 | 80.3% | — |
| 2009 | 226,390 | 2,209,566 | 80.8% | — |
| 2008 | 239,349 | 2,358,545 | 85.2% | — |
| 2007 | 271,507 | 2,683,575 | 96.9% | — |
| 2006 | 269,715 | 2,675,302 | 96.2% | — |
| 2005 | 228,608 | 2,285,851 | 81.5% | — |
| 2004 | 234,970 | 2,354,869 | 83.6% | — |
| 2003 | 233,574 | 2,392,031 | 83.3% | — |
| 2002 | 180,852 | 1,839,807 | 64.5% | — |
| 2001 | 189,985 | 1,963,115 | 67.8% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)