- Bioenergy
- Operating
- 10 · 100 · 1,000 MW
Map
- Bioenergy
- Operating
Red Wing: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Red Wing
Power plant · Waste to energy
Key facts
Power plant · Waste to energyran 62% of 2025 Retiring- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1949
- Net generation, 2025
- 125,450 MWh
- Grid
- 14 kV to Northern States Power Co - Minnesota (MISO)
- Location
- Goodhue County, Minnesota
- Operated by
- Northern States Power Co - Minnesota
Operations
- Net generation, 2025
- 125,450
MWh - Fuel burned, 2025
- 2,514,795
MMBtu - Capacity factor, 2025
- 62.3
% - Heat rate, 2025
- 20,046
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 78,748 | 1,558,783 | — | 19,795 |
| 2025 | 125,450 | 2,514,795 | 62.3% | 20,046 |
| 2024 | 123,213 | 2,637,596 | 61.0% | 21,407 |
| 2023 | 134,577 | 2,645,072 | 66.8% | 19,655 |
| 2022 | 124,534 | 2,348,954 | 61.8% | 18,862 |
| 2021 | 132,086 | 2,505,291 | 65.6% | 18,967 |
| 2020 | 145,165 | 2,611,801 | 71.9% | 17,992 |
| 2019 | 137,004 | 2,576,476 | 68.0% | 18,806 |
| 2018 | 121,339 | 2,415,176 | 60.2% | 19,904 |
| 2017 | 107,792 | 2,327,044 | 53.5% | 21,588 |
| 2016 | 128,139 | 2,668,677 | 63.4% | 20,826 |
| 2015 | 117,830 | 2,518,195 | 58.5% | 21,371 |
| 2014 | 109,528 | 2,304,120 | 54.4% | 21,037 |
| 2013 | 111,049 | 2,416,913 | 55.1% | 21,764 |
| 2012 | 103,887 | 2,133,524 | 51.4% | 20,537 |
| 2011 | 97,081 | 2,015,070 | 48.2% | 20,757 |
| 2010 | 92,989 | 2,078,058 | 46.2% | 22,347 |
| 2009 | 97,045 | 2,138,083 | 48.2% | 22,032 |
| 2008 | 99,907 | 2,167,602 | 49.5% | 21,696 |
| 2007 | 103,964 | 2,043,259 | 51.6% | 19,654 |
| 2006 | 97,593 | 1,789,437 | 48.4% | 18,336 |
| 2005 | 110,316 | 2,256,451 | 54.8% | 20,454 |
| 2004 | 113,280 | 2,201,557 | 56.1% | 19,435 |
| 2003 | 111,315 | 2,153,394 | 55.2% | 19,345 |
| 2002 | 116,878 | 2,206,788 | 58.0% | 18,881 |
| 2001 | 112,231 | 1,152,640 | 55.7% | 10,270 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)