Scattergood
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 22% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1958
- Net generation, 2025
- 1,664,827 MWh
- Grid
- 230 kV, 138 kV to Los Angeles Department of Water & Power (LDWP)
- Location
- Los Angeles County, California
- Operated by
- Los Angeles Department of Water & Power
Operations
- Net generation, 2025
- 1,664,827
MWh - Fuel burned, 2025
- 12,905,047
MMBtu - Capacity factor, 2025
- 21.7
% - Heat rate, 2025
- 7,752
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 945,245 | 7,683,063 | — | 8,128 |
| 2025 | 1,664,827 | 12,905,047 | 21.7% | 7,752 |
| 2024 | 1,055,478 | 8,847,691 | 13.7% | 8,383 |
| 2023 | 1,357,901 | 10,717,909 | 17.7% | 7,893 |
| 2022 | 1,888,081 | 14,349,213 | 24.6% | 7,600 |
| 2021 | 1,905,079 | 14,507,138 | 24.8% | 7,615 |
| 2020 | 1,701,685 | 13,626,758 | 22.1% | 8,008 |
| 2019 | 1,240,303 | 9,972,213 | 16.2% | 8,040 |
| 2018 | 1,786,840 | 13,440,225 | 23.3% | 7,522 |
| 2017 | 2,002,670 | 14,790,561 | 26.1% | 7,385 |
| 2016 | 1,419,960 | 12,533,422 | 18.4% | 8,827 |
| 2015 | 1,278,120 | 15,318,864 | 16.7% | 11,986 |
| 2014 | 1,133,912 | 13,660,011 | 14.8% | 12,047 |
| 2013 | 1,199,063 | 14,103,423 | 15.6% | 11,762 |
| 2012 | 1,087,220 | 12,573,267 | 14.1% | 11,565 |
| 2011 | 890,372 | 10,910,205 | 11.6% | 12,254 |
| 2010 | 1,014,306 | 11,611,516 | 13.2% | 11,448 |
| 2009 | 1,011,980 | 11,935,211 | 13.2% | 11,794 |
| 2008 | 1,301,624 | 15,064,611 | 16.9% | 11,574 |
| 2007 | 1,243,348 | 13,767,001 | 16.2% | 11,072 |
| 2006 | 1,502,587 | 16,931,206 | 19.6% | 11,268 |
| 2005 | 1,056,014 | 12,087,580 | 13.8% | 11,446 |
| 2004 | 1,741,384 | 19,107,566 | 22.6% | 10,973 |
| 2003 | 2,279,466 | 23,626,053 | 29.7% | 10,365 |
| 2002 | 1,284,789 | 33,860,830 | 16.7% | 26,355 |
| 2001 | 1,846,283 | 18,037,266 | 24.1% | 9,770 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.