Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 40% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2018
- Net generation, 2025
- 2,122,743 MWh
- Grid
- 230 kV to Public Service Elec & Gas Co (PJM)
- Location
- Middlesex County, New Jersey
Operations
- Net generation, 2025
- 2,122,743
MWh - Fuel burned, 2025
- 15,052,034
MMBtu - Capacity factor, 2025
- 39.8
% - Heat rate, 2025
- 7,091
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 1,172,645 | 8,362,230 | — | 7,131 |
| 2025 | 2,122,743 | 15,052,034 | 39.8% | 7,091 |
| 2024 | 2,601,491 | 18,016,984 | 48.6% | 6,926 |
| 2023 | 3,201,982 | 22,129,732 | 60.0% | 6,911 |
| 2022 | 2,691,071 | 18,468,736 | 50.4% | 6,863 |
| 2021 | 3,331,896 | 22,950,234 | 62.4% | 6,888 |
| 2020 | 3,667,054 | 24,772,704 | 68.5% | 6,756 |
| 2019 | 3,308,721 | 22,658,311 | 62.0% | 6,848 |
| 2018 | 2,092,350 | 14,441,187 | 39.2% | 6,902 |
| 2017 | 16,410 | 491,202 | 0.3% | 29,933 |
| 2016 | 71,240 | 1,108,851 | 1.3% | 15,565 |
| 2015 | 3,011 | 207,566 | 0.1% | — |
| 2014 (11 of 12 months) | 34,675 | 695,589 | — | 20,060 |
| 2013 | 19,118 | 380,667 | 0.4% | 19,911 |
| 2012 | 68,759 | 1,259,668 | 1.3% | 18,320 |
| 2011 | 83,148 | 1,411,239 | 1.6% | 16,973 |
| 2010 | 87,139 | 1,489,132 | 1.6% | 17,089 |
| 2009 | 30,347 | 677,268 | 0.6% | 22,318 |
| 2008 | 70,063 | 1,214,872 | 1.3% | 17,340 |
| 2007 | 119,450 | 1,902,695 | 2.2% | 15,929 |
| 2006 | 161,369 | 2,381,412 | 3.0% | 14,758 |
| 2005 | 338,216 | 4,674,924 | 6.3% | 13,822 |
| 2004 | 312,474 | 4,284,522 | 5.8% | 13,712 |
| 2003 (10 of 12 months) | 145,884 | 2,095,665 | — | 14,365 |
| 2002 | 319,371 | 4,467,806 | 6.0% | 13,989 |
| 2001 | 319,518 | 4,403,844 | 6.0% | 13,783 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.